  1. D

    New boiler

    Sadly they don't make them like they used to.
  2. D

    New boiler

    Glow worm system boiler no one has vented system any more. With a 15 year warranty. You'll probably have to upgrade your hot water tank to a tank with a modern high recovery coil.
  3. D

    High gas bills after moving

    Switch heating and hot water off. Is the gas meter static? Then you aren't loosing any gas. Heating on at night? Wandering around in shorts a T shirt?
  4. D

    Header tank steaming

    No you have a problem. Turn the pump speed down to 1 to see if this is any better. Otherwise needs the plumbing looking at. if possible convert it to a sealed system. Vented systems have no place in a modern heating system it's technology from the dark ages.
  5. D

    NEW PUMP FOR BAXI COMBI INSTANT 105E - IS THIS COMPATIBLE?

    Yes just needs the head swapping over.
  6. D

    Danesmoor 20/25 boiler ran out of oil bleeder not working

    Undo the pressure test point at the pump. It should push fuel out as it turns the pump over. If not possible if your ran out of oil the pump is now stuffed.
  7. D

    vented or unvented?

    If you have fairly poor pressure and flow then go vented with a big pump to supply the whole house.
  8. D

    vented or unvented?

    Unlikely that 4 showers will be running at once. 18 litres a minute is a bit on the poor side. I would fit an unvented cylinder and an accumulator tank. Feed all the showers from the accumulator and hot water tanks. I would use an ACV tank as these have extremely fast reheat times and...
  9. D

    Old boiler parts - help needed

    It's a halstead boiler you'll have more luck searching for the manual for halstead and then you'll know the part number to look for.
  10. D

    Central heating flowing into expansion tank

    Or the pressure to clear it. :)
  11. D

    Old boiler parts - help needed

    Get a local gas engineer to get you the right parts and fit. British gas are hopeless. The boiler is actually a Halstead although branded as wickes.
  12. D

    Ariston microGENUS 23 MFFI C.H overheats & red L.E.D loc

    Temperature sensor. The boiler is overheating and locking out. These are pants boilers to work on.
  13. D

    Downstairs radiator

    Connect up to outside tap with a hose. Push some cold mains through it. :-)
  14. D

    Central heating flowing into expansion tank

    The first thing to do would be turn the pump speed down to 1. Open all the radiator valves at both sides fully. If still overflowing put a push fit cap end on the expansion pipe over the tank. The expansion can go back up the feed pipe. Most likely cause is there is a blockage in the...
  15. D

    Worcester Bosch Boiler keeps getting air in pump

    Since this is a wall mounted boiler. If wall mounted and single pipe system with a non return valve then replacing the non return valve would be the first step. A leak in the piping is also very possible. Ensure there are no joints in the piping from the tank or those there are do not have...
  16. D

    Downstairs radiator

    Is the valve open? If so then the pipe is blocked.
  17. D

    Baxi Bahama 100 - Pressure and Noises

    Try topping it up a little with the filling loop. It should read 1 bar when cold.
  18. D

    Adding a radiator

    T off the 22mm pipes. You can then go to the new radiator in 15 or 10mm. My preference being 15 as it looks better and heats up faster.