  1. F

    Hi.....can none help me.....?

    I 8 avin 2 read dis stuff rite! A simple pause before typing and press of the spell checker can transform it into something we were taught at school. :) Pete
  2. F

    CH programmer that responds to external temperature

    What boiler do you have as a weather compensation unit usually just a 2 wire connection to the board in the boiler. Pete
  3. F

    Mystery controller

    As Gasman said it is a remote control for a trv. Pete
  4. F

    Minimum space required for 210ltr Megaflow + boiler?

    Have a look at Valliant and Megaflo web site as they detail this iformation in the installers download on whatever model you are after. Pete
  5. F

    Best way to join estate agents?

    In my early years I was stung and messed about by different agents. None of my colleagues will work for them and those who have gave up after a few months. As Andy mentioned if you provide your terms of contract that protects you and detail that the Agent is employing your services not the...
  6. F

    Megaflow - slight drop in pressure but noticeable

    Recharge the air bubble in the cylinder. Have a look at the instruction label on the cylinder it will explain how to do it. Pete
  7. F

    Best way to join estate agents?

    It is a good way to gain an awful lot of experience being called out all hours of the day and night---------------- and not get paid for your effort. Pete
  8. F

    immersion heater will only heat 2ft water then it goes cold

    Try lying down not standing you get a better wash that way :lol:
  9. F

    Plumber installed boiler - roomstat not compliant & no T

    I doubt you could get him/her back in as his contract was with the previous owner not you. Also building regs are different for new installations and replacement of existing equipment. Pete
  10. F

    Maintenance Work - plumbing price???

    That is a very good price you charged. Never mind the landlord you were contracted out by the Estate agents. I never work for estate agents anymore been stung several times by different ones from not paying to argueing the price and than charging the landlord full price. The landlord is...
  11. F

    Draining heating system - nothing coming out drain valve

    Hopefully near the pump you will see the motorised valves which usually have galvanised steel covers or white plastic On the side of the cover box will be a metal or plastic lever which can be pushed against the internal spring to open the valve. The lever has a little cut out in the body where...
  12. F

    Draining heating system - nothing coming out drain valve

    You can try using mains water to flush it out. Cap off the vent pipe with a push fit stop end and then connect a mains feed to the feed pipe coming from your feed/expansion tank and see if that blows it out of your drain cock. Pete ps have you made sure if you have any motorised valves...
  13. F

    replumbing for a new cistern

    Yes you can remove the drain cock and insert a tee with the drain on the bottom. Then you can have the feed off to the right to your cistern. You must reinstate the drain cock at the last point before the stop valve. Pete
  14. F

    Plug lifter

    Odds on the grub srcew has rusted leaving no head for you to get a grip on and turn. Use a torch and have a look first, I have had to drill them out in the past. Pete
  15. F

    Can I add a Heating Element to my InDirect Cylinder?

    I doubt you could sucessfully open the capping without distorting the main cylinder wall as they are very thin and that one looks pretty old and possibly full of limescale which will have set like concrete around the inside of the cap. Elements carry 3kw so you would have to ensure your...
  16. F

    Shower Pump advice

    A pressure regulating valve on the hot inlet to the shower can be set to the manufacturers parameters. Pete
  17. F

    Macerator Waste Pipe

    Syphonage is more likely if you have a drop of say 10m+ as this can cause a vacum and pull fluid etc from the unit. Always best to enlarge the bore on the run as soon as possible so go with the 40mm on the vertical. How long is your drop and do not forget to use a couple of 135d bends at the...
  18. F

    Macerator Waste Pipe

    Run it at the maximum bore you can achieve. We never run in 22mm even though it states the machine can handle it, we use minimum 32mm with long bends. 25mm mdpe would be difficult to connect to the soil stack and again it is quite thick so the nominal value is tight. Pete ps the size of the...
  19. F

    Is there a tool available?....

    This multi purpose tool is the one I use. Pete http://www.toolstation.com/shop/Hand+Tools/Plumbers+Tools/Multipurpose+Plumbing+Tool/d10/sd210/p65095
  20. F

    Feed for shower pump

    The internal pump on so called power showers are not as powerful as a seperate twin impellor pump. Pete