  1. F

    opal elson 600e immersion

    A simple resitance test through the element would tell you if it was functioning correctly. From experience these elements are a bugger to remove and the copper tank is pretty flexible. Install a lime scale resistant incalloy unit to extend longevity. They use the standard element. Pete
  2. F

    Which system to install - help please.

    I agree with John on the Jet Aga burner, have you thought about LPG storage tank instead of an oil tank on site? Pete
  3. F

    Thermostatic Shower Temperature fluctuates between hot/cold

    Are you sure the hot and cold feed to the shower valve are on the correct side, usually hot to the left side. Pete
  4. F

    steel versus copper pipework

    Copper does not rust! Pete
  5. F

    expansion vessel

    The heating circuit is seperate to the water in the cylinder otherwise you would be bathing in rusty coloured water. I think you need someone to attend to see exactly what system you have as you appear to be confusing the potable water side and primary heat circuits up. Pete
  6. F

    pipes vibrate after toilet flushed

    Make sure all the pipe work is clipped secure, if you cannot reach all of it say behind cupboards or boxing push some foam insulation on it to avoid any vibrations. Check your inlet valve on the cistern it may be worn causing pulses reverberating back up the supply pipe. Pete
  7. F

    expansion vessel

    If the vessell is red and connected to the heating/hot water circuit you do not need to touch any cold water stop valve. Check the pressure guage drain the heating circuit down (ensuring it is connected to that red vessell) Remove the vessell and then fit new one ensuring the pre charge pressure...
  8. F

    expansion vessel

    Legally you have to G3 certified to work on unvented hot water storage system. The expansion tank on unvented hot water systems are usually white or blue as they are for use with potable water. Red expansion vessels are used in sealed heating systems. Are you sure it is for an unvented hot...
  9. F

    Waste into soil stack

    I would recommend using a solvent weld boss insert as the connection is so close to the wc connection and you do not want any leaks from that do you. Pete
  10. F

    Problems with New Shower Pump

    Just use your mouth Kevin as once you hear the pump kick in just aim it into the bath/shower tray. It is only water, hopefully ! Pete
  11. F

    Problems with New Shower Pump

    Hi Kevin It sounds like you have an airlock. Ensure all service valves are open and turn on the shower on full cold, then take the head off and suck the water through, this can be done with the pump on. Hopefully this will pull the air lock up and out and get the flow switch activated to...
  12. F

    Confusion with "no call out charge"

    That all depends on the frequency of the "odd part being returned" My merchant has no quibbles with me as I have been a customer for over 12 years and it is the odd part, however that only comes with experience and yes I had a lot more odd parts to return a decade ago :oops: Pete
  13. F

    Megaflo or not? - advice on install

    I would say a 250l tank for 3 bath house is undersized as an unvented with good mains pressure and flow(something you must check before you even think of going unvented) would drain quickly if multiple outlets using at the same time. I do not know who lives in your house, all adults baths or...
  14. F

    Gledhill Stainless Lite Indirect

    Just as a matter of interest which way is the vessell positioned, air valve on top or bottom. Is the pipework to the vessell copper or a braided hose? I was called to deal with a similar issue years ago which was resolved by postioning the vessell with the valve on the bottom and piping in...
  15. F

    Shower pump making a noise and kicking in every five mins

    Could be a non return valve on the pump letting by, or if you have mixer valves they could be alowing cross flow which leads the pump to think it has a flow demand and so it activates for a few seconds. Pete
  16. F

    Shower pump/ water pump

    Have a look at the pump manufactures instructions they are quite detailed with simple diagrams to follow. Are you a plumber by trade? If so how are you going to balance the cold feed to the shower? Is the cylinder big enough for the demand if all pumps calling? Will you be using a surrey/essex...
  17. F

    unvented water cyclinder discharge

    You are correct most of the time they should be dry. If a relief valve operates at full flow you may have very hot water at 3 bar plus released so you need an appropriate discharge network in place. You should check with the manufacturer if they advise on a sump pump. Most sump pumps cannot run...
  18. F

    Best method for fixing bath overflow to waste pipe

    As said before silicone sealant and wrap some duct tape around the joint to keep it fixed in place, as these cheapo ones always come adrift if someone turns the screw on the waste outlet in an attempt to tighten the seal against the bath. Pete
  19. F

    Geberit Flush Volume Adjustment

    Hi Pete Are you using a pneumatic flush plate or rod plate. The rod/mechanical plates require you to hold the button in for a full flush. From memory you can only adjust these from 3 to 4 l and some require an extra fitting. Have a browse on their web site they have detailed specs on this...
  20. F

    Meeting building regs requirements for cavity insulation

    What cavity insulation are you using as rockwool and celotex have diff values. If you get stuck for cavity space a thermal laminate plaster board would bulk up your u values. Pete