  1. C

    No power to boiler (have checked other posts!)

    99% ofthe time that will be a pcb fault :)
  2. C

    Air brick for log burner in a new build

    I wouldn't fit a air brick I would see if your stove has a air supply kit that fits to the bottom of the stove and goes direct to outside. This way no cold air when woodburner is not being used
  3. C

    Boilers

    One modulates........ I would say the modulating is better.
  4. C

    To rip it out or start again?

    Hey that's not very nice! ( I'm not from norfolk I was invited to come ere to expand the gene pool ) norfolk has a good swimming team :) helps a lot with the webbed feet :)
  5. C

    draining ch system but have 2 drain cocks?

    Drain on flow pipe and drain on return pipe.
  6. C

    Vaillant boiler

    Get home serve back
  7. C

    Opening up toilet waste filled with cement

    You will properly find they up a bag in the pipe first then cement on top
  8. C

    Loud whining noise from Baxi HE Boiler system

    Also you don't have to be gas safe registered to remove te panel you have to be able to prove your competent. I know a few gas safe engineers that are **** and not competent so yeah :)
  9. C

    baxi 80e combi

    As above
  10. C

    space saving soil pipe

    1 world of smelly hurt 2 the colour
  11. C

    Help with gas fire -is it possible to downgrade power output

    Simple answer NO All basket type fires need at least 100cm of ventilation regardless of size plus extra ventilation if it is over a certain size Just remove it the fire or have the vent installed
  12. C

    Grant Vortex Condensing Combi 26 - no hot water

    Isolate cold water Remove flow switch Use multimeter to check for continuity when you flick the switch If that's working look at water pressure or any filters and then any Divertor valves etc
  13. C

    I've found my drain valve!

    We'll then it would be to easy for the next person to do any work on the system :) and we like to make it hard for everybody.
  14. C

    Ideal Isar HE30 woes.

    Also I would of changed the flame Sensor aswell as the electrode :)
  15. C

    Remeha Avanta Plus red light flashing/emergency mode??

    Sounds like a wireless thermostat receiver that needs re binding
  16. C

    Boiler is driving me crazy

    By pass is turned off and service valves are carp as only 8 inside the valve. I would drain and replace both one on the bott of the coil wants to be half open one on the upright pipe wants a automatic bypass valve fitting then see what happens
  17. C

    Passing Gas Safety Check on Gas Hob

    A vent into the conservatory wouldn't work as the size of the vent would have to be huge and wouldn't be able to be closeable and no fly screen. A extractor fan to the outside needs to be connected to the hob so the hob Can't be used until the fan is on, the best thing would be a ceramic hob...
  18. C

    intergas, bosch or neither?

    Viessmann have a **** heat exchanger ( intergas heat exchanger is at better) My company install Worcester we did use intergas but couldnt get the stock at the time but I would have a intergas anyday over any other boiler ( intergas stock is now fine but we have a large Bosch fan base in...
  19. C

    No hot water unless heating is on

    Or a faulty controller
  20. C

    Ideal Icos He18 PCB fuse

    Remove the old one and look on the fuse. I wouldn't be asking what size is the fuse I would be asking why has it blown