  1. C

    Existing Drain smells and big mice problem!

    Rats can't get through a hole the size of a pencil I keep rats they need room for there head just like cats do so your looking at a hole about 1 inch. I would say drain could be a issue but just a quick question does your washing machine waste do into a sink trap or a washing machine trap (...
  2. C

    Towel radiator

    Tcc heating that's what I tell my customers :) I got told that in school and it's stuck with me ever since
  3. C

    Potterton Prima 50F Boiler Issue! HELP!

    Foc you say, what about the 21 PCM you pay that isn't free
  4. C

    Ideal Logic 24 - condenser pipe

    It means only a competent person should remove the case on the boiler as it fitted with a seal and removal of this makes the boiler unsafe
  5. C

    Ideal Logic 24 - condenser pipe

    srink sorry :) ignore me :)
  6. C

    Room stat not connected...where is the stat wire?!

    is the boiler new ? somebody has more than likely cut them off when they changed the boiler. and didnt bother to put a new one in
  7. C

    Ideal Logic 24 - condenser pipe

    my bad that is the wiring in the boiler in some sort of black stink stuff :)
  8. C

    Ideal Logic 24 - condenser pipe

    condese trap leaking ? ( the wiring to that boiler have a load of tape over them that doesnt look to good )
  9. C

    Leaks in new central heating pipework

    2 bits of wood and a ply top :) you can buy proper plastic ducting but the wood one is better.
  10. C

    Taking out a decommissioned fireplace

    Stick an electric fire in
  11. C

    Leaks in new central heating pipework

    I live on the norfolk Suffolk bored I would of come and qouted for it. Copper pipe in th floor is fine even with joints as long as it is protected properly. Using plastic coated copper is ok but then that would be normally 10mm and can block easy, again plastic pipe in concrete floor still has...
  12. C

    Leaks in new central heating pipework

    How long after soldering the joint did he spray water at it ?
  13. C

    Worcester Bosch 40Cdi Bad Vibration

    15/50 seems small for 14 rads. I service loads if Worcester and I dot. Carry the service kits I did my first full strip down yesterday been working on them 5 years I service maybe 7-8 a week. It sounds like fault on gas valve or combustion setting I would get another gas engineer in. You could...
  14. C

    Potterton 28 HE Plus Combi Boiler Leak at 3 way valve and

    You need a angled pressure gauge and need to remove the bracket holding the green spark generator then you can get you hand in.
  15. C

    Electric under floor heating?

    This is plumbing and central heating not electrical and the answer is look up the fitting instructions all the information will be in there.
  16. C

    Hot water air lock question

    Do as Andy says but open the tap slowly and it shouldnt spray as much
  17. C

    moving a oil boiler

    +1 to boilerman 2
  18. C

    Header tank steaming

    Yes it will harm the system it's letting air enter the system meaning more sludge will build up and make the system worse.
  19. C

    Thermal Store Leak...

    it should be but that looks like its full of limescale? i might be wrong as its a thermal store but shouldnt it have a scale reducer fitted ? ( most boiler companies wont cover it if no protection, if water hardness is over 200ppm. ( i dont deal with thermal stores so i could be wrong)