  1. twgas

    TOILET CISTERN WATER INLET LEAK ON FLEXI HOSE

    Or it might only need a new washer
  2. twgas

    Hot Water Shut Off

    If you have an unvented cylinder, turning the cold, incoming main off will also turn the hot off. If you jhave spare new inserts why not use them although I doubt it would matter if the old ones were left in place.
  3. twgas

    STICKY STONES/CAT LITTER STUFF IN HALL CUPBOARD??

    Perhaps the last plumber you employed had a few spare!😈
  4. twgas

    Auto bleed valve for radiator

    Why would you want one? If you have to bleed it often there is a system issue!
  5. twgas

    Ideal classic ff250 tripping out on HW only

    Easiest fix! Is to bleed any air from the cylinder coil, there might be a bleed point on top of the coil connection, about half way up. May be there's a balancing valve that is turned (almost) off. It most likely is a bit more challenging! Possibly a blockage, I would suspect its a "gravity to...
  6. twgas

    Oil fired central heating - pressure problems

    You "turned off" the underfloor, switched it off or isolated the flow and return(s)? I dont believe the rest of the system cant be isolated! Although it might take some effort and maybe some building damage but if you have a hidden leak the damage will, in the long term, be much worse.
  7. twgas

    Alpha CD28C Boiler - Advice please.

    I also think you need a boiler repairer.
  8. twgas

    Can anyone help identify this pipework?

    That's an old water heater jig, top pipe is gas bottom the water connection, You'll need a RGI to disconnect it.
  9. twgas

    motorised valve

    Do you have only one 2port valve? Is the system fully pumped?
  10. twgas

    Baxi 105e Combi Boiler Hot Water Startup not always happenin

    More likely the HW diaphragm, you should only need a few litres per minute to fire boiler.
  11. twgas

    Short circuited the room thermostat now radiators don't work

    Maybe you've not connected the room 'stat correctly!
  12. twgas

    Installed new TRV- Kettling

    Take the head off the bathroom TRV, it might have been fitted as a by-pass and if so needs an open route through and back to boiler to dissipate the heat.
  13. twgas

    Is there a Programmer or Thermostat I am not aware of?

    I would agree with DH about the motorised valve but the rads getting too hot, with trvs, I would suggest dirt in the valves which will not be solved with lubricant, they will more likely need replacing.
  14. twgas

    Raven heat RSF84ET Problems - Pilot Light No Ignition

    I think you need a (registered) boiler repair man.
  15. twgas

    Radiators keep going off

    Not much info here! I would suspect youve got a seized motorised valve
  16. twgas

    Pressure loss in sealed central heating system

    A pressure drop of .2 bar is 12 hours is NOT negligible, although i would suggest, the first port of call would be getting the expansion vessel checked,
  17. twgas

    Potterton Pro Max Boiler - allergic to cold weather

    Is hot water ok? Do you have to reset several times before it works? Do you have plastic CH pipes?
  18. twgas

    Banging from Worcester 19/24CBI conventional boiler

    I would usually suggest sealing system rather than altering the config, however, worcester's cbi boilers, is my opinion, was probably the worst they've ever made and I wouldn't trust it to hold water under pressure!
  19. twgas

    Vaillant TurboMAX 837 losing pressure then Red Light

    A small amount of water (condensation) coming out the schraeder valve is normal
  20. twgas

    Vokera Combi Boiler doesn't fire up

    And the crystal ball says..........pass :mrgreen: