  1. twgas

    Boiler Replacement - The Big Guys vs The Little Guys?

    You need to compare the whole quote, the small guy will almost always be cheaper than the big guy. As for getting a better job, there are good and bad everywhere so, unless you know otherwise, its a bit of a gamble.
  2. twgas

    Mains water pump

    The pipe from the top of the cylinder, does it slant down toward the tee, or is that an optical illusion?
  3. twgas

    problem iflo 3 port valve install? help required please.

    A 3 port valve where the centre is an outlet rather than the inlet
  4. twgas

    Potterton Myson Boiler

    Let me get this right: you dont heed advise when it comes to the safety of the lives of your family and neighbours but will, however, accept advise on a good price for a fan, whether thats the problem or not!
  5. twgas

    MAIN combi 30 he LED's Water & temp

    The light staying on is usually due to either the microswitch or the pushrod that operates it sticking. This will also keep the pump running and temp lights on
  6. twgas

    MAIN combi 30 he LED's Water & temp

    Try adding new info/questions in a new post (on same thread), keep editing 1st post means we have to re-read time and again!
  7. twgas

    problem iflo 3 port valve install? help required please.

    DH, have you ever seen a drayton tam4?
  8. twgas

    problem iflo 3 port valve install? help required please.

    That looks like an ACL drayton valve, if so its connected wrong, and which way is the pump pumping?
  9. twgas

    problem iflo 3 port valve install? help required please.

    You would think so, but it might be down to the whole system configuration.
  10. twgas

    problem iflo 3 port valve install? help required please.

    I think the pumping over IS your problem, if you move the vent to where it should be your problem will more than likely be solved.
  11. twgas

    problem iflo 3 port valve install? help required please.

    Is it still pumping over? Can you post pics of the pump/valve/cylinder set up?
  12. twgas

    Potterton Envoy Leak

    you have compromised the room sealed chamber, i would suggest you get a rgi. I suspect the bit thats leaking may well be obsolete.
  13. twgas

    Vulcan Continental boiler

    :shock: :lol:
  14. twgas

    Worcester Greenstar 25Si DHW problem

    The pressure issue will be due to an issue with the vessel, needs recharging. The hot/cold scenario has been done to death, will most likely be the plate heat exchanger being blocked with dirt.
  15. twgas

    C & M Britony Combi - Programming

    Then a new timer looks most likely
  16. twgas

    betacom glow worm 30c condensate trap

    I would say you need a gas safe engineer, flashing 90 means lack of flame, which being gas you are very unlikely to get help here. And its extremely doubtful youd have 4 faulty traps! I dont remember ever changing a trap on a betacom or any similar type of boiler!
  17. twgas

    Mains water pump

    Upload the pics and someone may be able to help\advise.
  18. twgas

    betacom glow worm 30c condensate trap

    Why is it being changed?
  19. twgas

    S Plan query

    Not exactly. The ons from the zone valves will be connected to the connection normally used for just heating.