  1. twgas

    Help needed wiring digital thermostat to old system

    I think you've got the wrong thermstat, the rf is wireless whereas your old one wasn't
  2. twgas

    Radiator valve only turns a tiny bit

    Reinsert the spindle but 'unscrew it' when you've pushed it as far as you can, although I say push very little force should be needed. When you've 'unscrewed' it till it stops refit the gland nut in the normal way but only finger tight. You should now be able to 'unscrew' the spindle some more...
  3. twgas

    Filling loop & Pressure gauge - Fitting

    Easiest, and most readily available bits, 22*22*15 tee (compression or solder, whichever suits you) then 15mm cu*1/2fbsp and 1/2*1/4 brass bush. Or as him above says :mrgreen:
  4. twgas

    Intermittent problem - Boiler not lighting

    Get it serviced, and dont forget to tell the service engineer that you have a problem. Quite a few poss causes of no heat!
  5. twgas

    Heating thermostat

    oh dear!!!
  6. twgas

    PB or PEX

    Copper, copper, copper!!!!
  7. twgas

    Power surge near boiler- control unit and boiler now dead?

    If the immersion is fed by its own fuse then I'd remove said fuse in case someone, inadvertently, turns it on and stops the boiler again.
  8. twgas

    Boiler kettling, pump very hot, some pumping over.

    Why were the rads replaced; asthetics, leaks etc? System needs checking for correct instal/design, then, I would suspect a GOOD powerflush is what you need.
  9. twgas

    Moving boiler from kitchen to cylinder room

    Have you thought about a replacement heat only boiler in same place as old one, probably the cheapest option
  10. twgas

    One for BG guys

    Personally i do 4or 5. Today however it was just 1. But to be fair it was getting floors up and finding blockages!
  11. twgas

    To drain or not to drain

    I would say it depends on the system and what exactly needs to be done, and how confident you are :mrgreen:
  12. twgas

    One for BG guys

    Not really, jobs that are booked in get allocated as and when the next local guy is available so in theory there should only be 1 job lined up for anyone. Parts jobs are a bit different, they have to be lined up to, usually, the engineer that ordered it.
  13. twgas

    One for BG guys

    Things have changed recently, the focus is now on getting the job done right, not in the fastest time possible. However for planning work in the office allow about a hour per job
  14. twgas

    Vaillant EcoTech 624 pressure mystery

    No probs, I've been called worse than that :lol: Did yoy empty the boiler of water AND leave the drain point open?
  15. twgas

    Vaillant EcoTech 624 pressure mystery

    Is that (0.9bar) the air charge in the vessel? And how exactly did you check it?
  16. twgas

    Ideal Standard Concord WRS 40 - no gas at pilot

    Get a gas safe registered engineer, gas advise on here is a no-no.
  17. twgas

    Vaillant EcoTech 624 pressure mystery

    I'd agree with flameport, the expansion vessel needs checking, even if in your infinite wisdom it is "ok"
  18. twgas

    No hot water unless tap is turned on full

    http://www.freeboilermanuals.com/pdf/baxi_disc/Combi-105HE.pdf Page 28.
  19. twgas

    No hot water unless tap is turned on full

    Then its probably the venturi
  20. twgas

    No hot water unless tap is turned on full

    diaphragm, possibly, or venturi. Had any parts recently?