  1. twgas

    Vaillant Turbomax Plus 828e - no hot water, CH OK

    I'm amazed that you have the exact same problem yet you have different lights showing to op. :shock:
  2. twgas

    Replacing tap on sink - can't undo the (pushfit?) hoses!

    If your new tubes are longer than the old ones you could try cutting the copper just below the plastic fittings. Best bet would be compression ends on the tubes but it sounds like you've bought BSP ones.
  3. twgas

    Replacing tap on sink - can't undo the (pushfit?) hoses!

    The grey collar at the bottom of the fitting pushes up into the white bit, then the whole thing will pull off. You wont find any thread on the pipe.
  4. twgas

    Microbore Issues - Some resolved - Need advice for others!

    Its a complete ball-ache but you need to find which pipes are blocked then either clsean out or replace them
  5. twgas

    CH Water temperature setting for Glow worm 30cxi?

    I would say about 3/4 which will be roughly 70°.
  6. twgas

    Boiler not firing for CH - duff roomstat? Theben Ramses 811

    Motorised valve looks to be most likely suspect.
  7. twgas

    problem iflo 3 port valve install? help required please.

    It will if the last demand was for CH.
  8. twgas

    problem iflo 3 port valve install? help required please.

    Cold feed should be between open vent and pump and less than 6 inches from the vent
  9. twgas

    Central heating pumps

    You wouldnt be doing a gas course by any chance?
  10. twgas

    Ikon 28t combi boiler

    If its not worked since the salus installed its either wired wrong or faulty. Pics of the wiring might help
  11. twgas

    Pressure relief valve

    The pressure releif valve does not increase the pressure, thats the filling loop. You could let some water out of a radiator bleed valve, but if the filling loop is still on it wont happen.
  12. twgas

    Air in heating system

    What boiler/system do you have? Do you have to add water/pressure to system? By "over bleeding" do you mean leaving bleed nipple open after the air stops and water comes out?
  13. twgas

    Washing machine tap

    Try a small adjustable spanner on the bit where the tap handle was!
  14. twgas

    possible 3 port diverter fault?

    You need a multimeter, and to know how to use it, to do some diagnosing.
  15. twgas

    Vokera Boiler Problem

    Get a different plumber/engineer, your guy is useless!
  16. twgas

    Drained Central heating still has water in pipes

    If you're going to remove them when you do rads why not use draincocks, you can then reuse them at the new rad!
  17. twgas

    Pressure refleif pipe - routing

    Prv discharge pipe from heating can be extended, if its on an unvented cylinder youd need a g3 plumber. It needs a fall of any description and must terminate safely. That , basically, means at low level or swan-necked back to wall, but not where someone can stand right under it.