  1. twgas

    Heating with 2 down feeds issue

    Air. Turn off the hot ones and as the others heat up turn them off until you get the last one going, you can then turn them back on, let them get properly hot, before turning off.
  2. twgas

    Upstairs radiators won't fill up after draining

    I've not read this whole thread but try Tracking along as much of the pipe, as you can, with a magnet, if it sticks to the pipe there is magnetite in it which will reduce or stop circulation.
  3. twgas

    Rusted and damaged radiator valve on back of radiator.

    Have you tried pliers or small adjustable spanner on the bleed key for extra purchase?
  4. twgas

    Rusted and damaged radiator valve on back of radiator.

    Does it screw straight into the rad or into a bush/plug?
  5. twgas

    bdr91 wiring advice

    Depends on your system and boiler, but my crystal ball needs a new battery!
  6. twgas

    Cutting 2mm off a length of 15mm copper pipe

    Cut it off the other end and move it along a bit :mrgreen:
  7. twgas

    extending boiler flue through a new 'lean-to'?

    I suspect the flue bits to do as you want are available, however, whether the manufacturer would approve of it being outdoors is another matter.
  8. twgas

    air trapped in boiler circuit

    Can you post a picture of the pump, motorised valve(s) and the pipework around that area.
  9. twgas

    Upstairs radiators won't fill up after draining

    you could try draining and refilling, but that often entrains more air. find the cold feed connection and cut it out.
  10. twgas

    service cost

    rip off.........£149.98 is more realistic :mrgreen:
  11. twgas

    Upstairs radiators won't fill up after draining

    looks like sooey got it right, if you feel competent to clear the cold feed do so, if not call a pro.
  12. twgas

    fully pumped or gravity fed

    Try refittin the prog and then turn on the CH only, (set to fully pumped on back of prog) see if it works
  13. twgas

    Central heating not working

    Sounds like you need a new receiver.
  14. twgas

    Noisy air filled system

    You should have put an air release on the pipe at the 3port valve. As it is the easiest way to bleed it is to loosen one of the compression joints, probably on the gate valve, and catch the water in a tub.
  15. twgas

    Central heating not working

    check for mains power on the white wire to the valve, when there is a call for heating .
  16. twgas

    Noisy air filled system

    Got any pics of the new pipework setup?