Search results

  1. andyr123

    Indicators not working on my Renault Zoe EV

    thanks i will hook a meter up to the hazard lights switch and see
  2. andyr123

    Indicators not working on my Renault Zoe EV

    thanks, one of the first things i done - didnt do anything, fault was still there when i tried out the indicators again
  3. andyr123

    Indicators not working on my Renault Zoe EV

    Hi all, - the Indicators have stopped working on my Renault Zoe EV. If I press the Hazard switch on the dashboard the 2 green indicator lights on the dashboard flash as normal, but no indicator lights show outside. Then if I turn off the hazards and start the car and put the right indicators...
  4. andyr123

    Balancing Radiators some colder than others

    thanks all for your inputs and suggestions. I have just been out to boiler and pump (grundfoss clone) was set to speed number 1 for some reason - so after setting to speed 3, even though now pump is noisier of course, but all radiators appear to be piping hot now.
  5. andyr123

    ( Nissan Note 2019 ) High Beam headlights switch not working properly

    its not just the HBA (high beam assist) that has the problem though. I can live without HBA, its the fact that when at night to get the High Beams to come on I have to push the stalk and hold it there to have high beam
  6. andyr123

    ( Nissan Note 2019 ) High Beam headlights switch not working properly

    Yep can get main beam only by pushing and holding switch forward , or pulling switch back as if flashing someone - if I let go the switch returns to middle and high beam bulbs turn off
  7. andyr123

    Balancing Radiators some colder than others

    i'm checking every 10 minutes to see which radiators are the hottest , give them a time to heat up :)
  8. andyr123

    ( Nissan Note 2019 ) High Beam headlights switch not working properly

    Hi there - Nissan Note 2019 with automatic high beam assist . cannot get the Headlights to stay on Hi Beam . Got to pull the beam steering stalk as if flashing main beam or push and hold stalk forward to switch on main beams . Have checked fuses , and in any case if it were a blown fuse for...
  9. andyr123

    Balancing Radiators some colder than others

    on the cold radiators open up the lockshield more? or close down lockshield more?
  10. andyr123

    Which side of radiator should bleed valve be on?

    oh good, it does not matter then . Yes all radiators are level on the wall
  11. andyr123

    Which side of radiator should bleed valve be on?

    Hi all . I have just noticed that the bleed valves on a lot of our radiators are on the same side as the TRV's - some other radiators have them opposite the TRV/Flow side but majority on the TRV side. Does it matter where the bleed valves are positioned on CH radiators? I would have...
  12. andyr123

    Balancing Radiators some colder than others

    hello all can I have some advice / experiences please. if a radiator is cold/colder than the others on the system would I be looking to open the return lockshield valve more, or less? all rads have thermostat valve (TRV's) on which is turned up to highest (5) and radiators all bled so its no...
  13. andyr123

    16amps on a 13a socket

    If you have a ring mains to the socket does that double it up to 54amps rating or is the rating still 27amps?
  14. andyr123

    16amps on a 13a socket

    Thanks. I was getting info from here: https://www.spwales.com/cable-size-current-rating-chart
  15. andyr123

    16amps on a 13a socket

    Is the 2.5mm wiring behind the double 13a socket OK for it? - I see 2.5mm is good for 24amp single phase but does that double to 48amp on a ring circuit? - if you plugged in 2x 3kw appliances that would amount to 25amps wouldn't it? so even if the socket would withstand it what effect would that...
  16. andyr123

    16amps on a 13a socket

    if you plugged in 2 plugs of heavy appliances of 2kw each (say a tumble dryer on full heat, and a 2kw Fan heater) into a double socket wall outlet 2x2kw @240vac = over 16amps - yet a 13amp twin socket outlet is designed to plug in 2x 13a plugs , how is that? there would be a tremendous amount of...
  17. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    Yep our boiler, PRV fitted and no valve between F&E pipe and CH pump on the return and vent pipe lagged and goes over top of header tank and AAV fitted on flow of coil pipe of immersion cylinder
Back
Top