  1. C

    Which condensing boiler (in UK) ???

    Why only stainless steel ,what have you against an alloy heat exchanger ?
  2. C

    gas combi-boiler doesnt like cold weather!

    If your pressing the red button to re start the you must have either a slow flashing CH light or both CH and DHW flashing slow at the same time if its both then its an overheating fault if its only the CH then its a flame failure fault . so one light or two flashing ? ?
  3. C

    WORCESTER24cdI bf

    In that case its probly reached temp on the primary stat so you eaither have an air lock or your pump has stuck.Try removeing the crome screw on the front of the pump (it will dribble water so have a cloth under it) and turn the shaft with a small screwdriver to free it this will also release...
  4. C

    Bolier not obeying thermostat

    Assumeing your talking about a room stat. The easy way to tell is to totaly disconect the room stat (with power off etc) then see if the boiler still runs on heating ,if so then its a board fault if not its the room stat, more chance of a faulty room stat.
  5. C

    WORCESTER24cdI bf

    Does the ch light flash slowley after the failred ignition. Did you alter any external electrics or gas when fitting the towel rail ?
  6. C

    Worcester highflow 3.5 - Help with DHW & DCH - LONG !

    Remove the tin cover on the diverter valve with the power off and atach meter to the two leads feeding the syncron motor with the power on and a dhw demand it should power up if so and it fails to move then it will require replaceing.
  7. C

    Worcester 350 Combi-expansion vessel

    First off your diagnosis is right the expansion vess will have to be replaced, its one of the easy ones to do .Drain down the boiler from the brass drain point beside the by pass screw underneath then undo the philips screw holdindg a sliding plate to the left and below the vessel ,remove screw...
  8. C

    Worcester 28i junior - high pressure

    Give Worcester a ring at worst theyl charge you £245.00 for a new heat exchanger fitted but as its only just out of warenty they usually wave the charge. As you say you did not adjust any thing pror to the fault but to make sure look under the lower right hand side of the boiler if you have a...
  9. C

    worcester 240 combi boiler

    £185.00 from Worcester if your outside the london area ,thats upto 3 major parts and all labour.
  10. C

    Worcester 9.24 boiler problems

    First things first that relay is still available but i dont think its the problem just a "last straw . Your model has a permenant pilot and a fan, thats poss the problem ,the ignition board fitted to your boiler has a large ceramic resistor fitted to it this holds the fan on low speed ,if the...
  11. C

    Worcester Boiler - Pressure Problems On-going

    You said "the plumber isolated the heating from something else " if he isolated the boiler from the system to check for pressure loss he would have to have used the isolateing valves (bulkhead) under the boiler when the system was cold and left it for at least 8 hours to see if the loss was on...
  12. C

    worcester 240 rsf h/w prob

    Should have gone to "Specsavers" ________________________________ lynda, moderator Post locked, so new posters can not break forum rule 7
  13. C

    worcester 240 rsf h/w prob

    On the 240 its usually just the diagphram in the diverter valve,the small black plunger should come out and contact the two micro switches when you open a hot tap ,you can unclip the micro swwitch box and depress the micro switches manually to tast that they work ( carfull as one is 24v but the...
  14. C

    Worcester heat slave pressure problem

    The heat slave has one of two types of expansion vess a square one and a round one if its the square the flexi hose feeding it has a habit of blocking up giving the symptoms of a faulty expansion vess (your symptoms) to check if its the hose raise the system pressure to 1.5 bar then test the...
  15. C

    Setting the Worcester 240 combi clock

    If your timer display is flashing and scrambling on a 240 it can be re set by pressing two alternate buttons at the same time, thing is i cant remember ? but basicly if you cover three buttons in a row and press the outer two it should re set back to 12 if you get the wrong buttons nothing...
  16. C

    Outdoor Boiler Anti-freeze

    Is your Grant a system boiler or a combi , if its a combi then a frost stat would be recomended as with only anti-freeze you would have no latent heat to protect the mains water pipes at least with a frost stat it will come on and heat the w/w heat ex plus have you bugeted for replaceing the a-f...
  17. C

    WORCESTER 19/24CBI

    Before you change the pcb change the flame senser lead ,it often sits too close to the burner and sufers allso reverse poarity will give the same fault but only if someone has been working on the mains prior to the fault. No min gas pressure adjustment on the gas valve but does the flame pattern...
  18. C

    Yet another central heating problem....but I'm a lady!

    DONT check the presure in the expansion vess, not on a 28i it has one of the most reliable you may let to much air out when testing, no need to check unless you pressure gauge is riseing upto three bar when htg is on with the fill lopp discnected ,if its not riseing above the norm then its ok...
  19. C

    Low hot water pressure

    has your cold water flow rate dropped if its the same as previous then to have a suden drop in flow rate on dhw could be the inlet filter blocked or the flow restrictor blocked the first is a pig to do the second about30mins by the book. can you measure your max cld flow rate at the taps then...
  20. C

    Worcester 24i Combi

    Try the re set button on top of the boiler on the right (not the test point beside it)