  1. C

    Worcester Bosch 24 cdi rsf - no hot water

    It does sound like a diverter valve fault if the demand light does not come on when you run the hot tap, if you do it your self replace the "o" rings provided .
  2. C

    Worcester 24CDi Combi

    At this time of year the hot water will only be just over 40 degC above the cold water temp at full flow 9lt per min if have your corgi man check the inlet gas pressure with the gas valve mode switch set on max ,if the bottle is conected by a hose then he should have around 35mb inlet (working...
  3. C

    Worcester CD28i hot water problem

    Get a new hose ,
  4. C

    Worcester CD28i hot water problem

    That fast flash indicates a flue fault, most comon on the 28cdi would be the air hoses from the fan to the air pressure switch, they can perish at the fan end ,any tiny crack or hole will drop out the air pressure switch particulally on max gas (hot water), other than that your fitter would have...
  5. C

    worcester 24i

    If your sure you have turned off the fill loop taps then remove the flexi hose, you wont get wet if turned off. the pressure should drop as you remove water from the system as long as you have not shut off the flow and return isolateing valves.
  6. C

    Wocester 240 H/W but no C/H

    Your pump must be working ok or it would overheat big time on hot water. check both your iso valves to the htg are open and clear, the diverter valve should rest in the ch position (plunger in ), the 240 is at least 7 years old why was it took out ?
  7. C

    How to replace expansion vessel

    If you get water out of the air inlet point of the expansion vess then its duff and has to be replaced. if its the 35cdi MK1 then its very easy to change (boiler has two pumps) if its the 35cdi MK2 (1 pump ) then its a Corgi job as the gas valve has to come out and its a bit of a pig to get out.
  8. C

    Condensing boilers - new rules

    Your point ! !
  9. C

    worcester combi problem

    If the dhw light does not come on when you turn the tap the as sugested its prod the diverter valve diagphram, not a diy job on the cdi.
  10. C

    Worcester Bosch 280 RSF(domestic water problems)

    If the pump runs slow on the 280 the burner usually drops out before it gets to overheat but if it overheats when on dhw then its prob poor circulation in the water to water, hard to test on a 280 but if you have a poor temp rise say less than 30 deg C at 10lt per min then it points to the water...
  11. C

    Condensing boilers - new rules

    The condensate pipe is a gas safety issu as it is an integral part of the gas appliance, if you thik about it its the bottom of the flue, if the syphon leaks and it looses its seal then product of combustion will pass down the pipe ,thats why some commisioning instructions tell you to fill the...
  12. C

    worcester combi problem

    What Worcester is it ? around 40 diff models so quote the desccripton on the front could be just 3 numbers say 240 or 24cdi that kind of thing only 60% have diverter valves.
  13. C

    Worcester Bosch 14/19 doesn't stay alight

    The built in twin chanel timer will sometimes give a problem sim to what you describe but you can usually se the display acting eratic, is that the case. ?
  14. C

    Boiler recommendation.

    The 28 j is upto your heating demands but not upto an aditional en suite it has a flow rate of 9lt per min so would only do one tap at a time
  15. C

    Worcester Bosch 280 RSF(domestic water problems)

    If your boiler overheats only AFTER you turn the tap off then it has to be the flow switch sticking, easy to clean out as the paddle is inly held in by a large plastic grip, obviously turn off power and water first (its the housing that blocks up so clean out in situ useing smal hard brush or...
  16. C

    Which boiler make to go for

    35 HE PLUS is a good boiler with very good performance and no bad points other than a bit on the large side.
  17. C

    Combi boiler hot water problem

    What is the model of the boiler ,your discription sound like a 24/28 cdi not a si ? ?
  18. C

    worcester boiler 24cdi building up presure

    If your pressure does not fall but stays at 3 bar plus then its your plate heat exchanger that passing primary to second , if the pressure does fall to well below 1 then back to 3 when the central htg is on then its prob your expansion vess as said above.
  19. C

    worcester bosch 280 rsf NO IGNITION

    Overheat re set button is on top of the controll pannel behind the front panel.
  20. C

    Replacing District Heating

    Dont buy a boiler unless you can get backup during and after the warranty has ran out. try phoning heating supplers etc and see if you can get anyone who can supply parts or has even heard of it ,i haven't. A combi could give the same or better pressure than your power shower it depends on your...