  1. S

    network fault monitoring

    is it possible for the electricity network operator to monitor the integrity of the Neutral conductors around a network? if so, how is this done?
  2. S

    merlingerin dp fusebox id pls

    can anybody identify the exact model of this fusebox? from memory it has Merlin Gerin DP MCB's in it. thanks
  3. S

    radio teleswitch

    I seem to recall that there is a little tab that pops up inside the window of a teleswitch to visually indicate which of its 'outputs' are energised... is such a facility common to all of them?
  4. S

    radio teleswitch

    How do radio teleswitches receive the switching signal? I recently had an "issue" where a teleswitch controlled storage heater circuit was apparently not energising in the periods when it should have been energising. it appears to have cured itself. This happened at a time when the property in...
  5. S

    wired fire alarms

    the aico system is interesting indeed, a lot of function for the money. I had never seen them before. The mic idea is a very good one. was it at all tuned for the piezo bleeper or just a wideband noise amp?
  6. S

    wired fire alarms

    It's to provide an auxiliary closure to operate an autodialer. The Kidde system appears to float the line in normality and then swings to +9Vdc in alarm condition. I wondered exactly how "proprietary" the interconnect might be across different manufacturers, mainly out of interest. My kidde...
  7. S

    wired fire alarms

    Anyone know how does the interlink system work on wired mains-powered domestic smoke & heat heads? if so, please might they explain? I mean, I know that they use a separate conductor for the link, but what signaling is applied to this line by an initiating head to ensure that all the other...
  8. S

    Lambda

    so lucky
  9. S

    Lambda

    I think that the sign is supposed to allay any "death ray" fears amongst (Daily Mail reading) travellers. I did not raise it with anybody at the airport for fear of subjecting myself to an "enhanced" search.
  10. S

    Lambda

    Not strictly on-topic but I felt the need to share this amongst pedants. seen at Glasgow Airport yesterday.
  11. S

    LED light fitting

    True. I had noticed that the insulation is not 1 layer of pvc, it is something (slightly) tougher indeed. the DI classification may well be defensible. My main justification for earthing the backplate was the little HF LED driver module. I have seen enough of them fail catastrophically to...
  12. S

    LED light fitting

    I didn't use any diodes in my mod...? I will see if Trading Standards are interested in this. Harking back to post nr.3, where B-A-S implied that I have made the light more dangerous. I have taken some pains to illustrate the hard facts of this case. in light of these, have I actually made the...
  13. S

    how thick can you reasonably skim a drywall finish?

    I have just ripped off a tired old internal wall. The composition of the old wall is/was: studwork: 12mm plasterboard : 12mm plasterboard : 4.5mm faced ply the only reason it came off was that the faced ply "trawler-wall" was deemed aesthetically displeasing. I have discovered that I can...
  14. S

    LED light fitting

    Yes, exactly. The voice of hard practical experience there.
  15. S

    LED light fitting

    No, absolutely - it seems very unlikely that the case could become live. this is said without the benefit of the same hindsight that led to CPC conductors being installed as a matter of course. On a well-made product, it should naturally be very unlikely that the case could ever become live. but...
  16. S

    LED light fitting

    Double Insulated means that there are (at least) 2 insulating layers between the user and the juice. Maybe "Air" can be one of these insulating layers. (?) somehow I doubt it.
  17. S

    LED light fitting

    The enclosure was and remains an exposed conductive part (or exposed-conductive-part, if the hyphens are important - or did you mean to write Exposed Conductive Part?). I think that is basically my point. the product is marked double insulated. the product is not double-insulated. Is it? ...
  18. S

    LED light fitting

    Indeed; I took said isolated and exposed piece of metal and connected it to a CPC. In its original incarnation, if a "line-to-chassis" fault had developed, the exposed metallic chassis would have become line potential and likely no disconnectors would have functioned. In its modified state, if a...
  19. S

    LED light fitting

    I did say comments appreciated..? ok - more dangerous - this is what I was afraid of - break it down for me B-A-S, please!
  20. S

    Turning ones back on suspect electrics?

    always keep your back to iffy electrical installations, especially when energising! Nine times out of ten, if it doesn't go bang right after you throw the switch, the job's a good 'un.