  1. bellairaphon

    CH System - Choices?

    I would speak to UU and request that they check their end. All your responsible for is the pipe in your boundary. However connecting back to the main could possibly incur charges to you if they find nothing wrong and you still want the work doing. But either way a 750ltr accumalutor should be...
  2. bellairaphon

    CH System - Choices?

    How far is it to the stop tap outside?
  3. bellairaphon

    CH System - Choices?

    An accumulator is better than a break tank. I'm saying that as in open vented/ sealed system. So you will have an open vented coil in and unvented hot water cylinder.
  4. bellairaphon

    Baxi Solo 3 boiler problem HELP !!

    Registered gas installer mate.
  5. bellairaphon

    CH System - Choices?

    4ltrs a min is pretty poor. Only way would be run a new pipe. Accumulator would be an ideal set up. Tie in with a wras pump. The wood burner would need to be on a open vented system. So if you went for an unvented cylinder it would have to be twin coiled. Nath
  6. bellairaphon

    Baxi Solo 3 boiler problem HELP !!

    Gas turned on at the meter? Nath
  7. bellairaphon

    CH System - Choices?

    What's your incoming mains flow and pressure during peak demands? Nathan
  8. bellairaphon

    Drill damage to 15mm Gas pipe

    I'd recommend getting the pipe re-run. Nath
  9. bellairaphon

    Boiler giving hot water and then freezing, then hot!

    Yeah I would. It's not that hard to swap if it is the plate hex. But getting a breakdown engineer. He should be able to diagnos the fault. Nath
  10. bellairaphon

    Logistics of fitting a new CH system w/out messing up house

    Cheap price yes. But before you say yes ask what boiler is to be used. Its all well and good saving cash on the install. Then forking out after the 2 year warranty runs out. As cheap boiler manufacturers make there money back through the price of parts.
  11. bellairaphon

    Boiler giving hot water and then freezing, then hot!

    Possibly scaled up plate heat exchanger.
  12. bellairaphon

    Radiators hot downstairs, cold upstairs. Need help!

    Is the upstairs thermostat turned up? Do you know where your zone valves are located? Nathan
  13. bellairaphon

    British Gas Advising New Boiler Due to Obsolete Parts

    Parts are available for your boiler.
  14. bellairaphon

    No Central Heating without Hot Water

    Yes should be y plan. If you can identify the wired in the wiring centre then you should not have a problem. Nathan
  15. bellairaphon

    No Central Heating without Hot Water

    You have wires in ch on hw on but no wire in hw off. Means your valve will sit mid position. And will only shut off when the stat is satisfied presuming its wired correctly upstairs. Nathan
  16. bellairaphon

    CH System - Choices?

    I'm just over the Pennines if you get stuck with finding an installer! Nathan
  17. bellairaphon

    Problems with Vaillant Turbomax combi not firing up on HW

    What reason did he give to replacing the gas pipe? Also what light does it get upto before it fails to light? Nathan
  18. bellairaphon

    honeywell DT92 wireless thermostat

    Do you have another 2 wires for the L N? If so then depending on your boiler some boilers have a live out switch live in. As live out would go to A and switched live back to your boiler from B. another way is a loop so aslong as its in A/B. and some just have a live in. Nathan