    no hot water

    No need to reset the boiler as it's working. The valve sounds like a 3 port so when a hotwater demand is called by itself then the valve is not used. Voltage goes from the programmer HwON to the Common on the cylinder stat. So to check your clock simply test for voltage at the stat. If you have...
  2. bellairaphon

    no hot water

    turn the heating off but leave the hot water to constant. Does the boiler fire? What set up do you have 1 x mid position valve or 2x2 port? Nath
  3. bellairaphon

    Perpetually leaking tap unions - help!

    Try putting a 1/2" fibre washer into the backplate. Nath
  4. bellairaphon

    vibrating cold supply

    A pressure reducing can be fitted and a mini expansion valve should sort the problem, around £50 in materials and fitted as close to the stop tap. Nath
  5. bellairaphon

    Ideal Icos H243

    And do both just have 2 pipes going into either end?
  6. bellairaphon

    Ideal Icos H243

    How many motorised valves do you have? You should be on a s plan 2x2port valves or a 3 port with a extra zone valve on the pipe leading to the cylinder. Nath
  7. bellairaphon

    Potterton fault has the repairmen stumped!

    No worries, hope you get someone who will sort it for you. Nath
  8. bellairaphon

    Potterton fault has the repairmen stumped!

    Yeah. That activates the microswitch to tell your boiler the pump is on. Nath
  9. bellairaphon

    Potterton fault has the repairmen stumped!

    Have they checked the differential pressure diaphragm?. It could be sticking. Nath
  10. bellairaphon

    Worcester 24i re-pressured but not firing

    Not had much dealings with the 24i Rsf Tony just the 28i but sure the overheat is near the front on both models. But I could be wrong! Nath
  11. bellairaphon

    my home boiler issue again

    Sorry Dan I couldn't make it out. Seen in now all with the power of zoom. Sorry William I need to shut up and go to specsavers. Nath
  12. bellairaphon

    Worcester 24i re-pressured but not firing

    Your welcome. Glad you realised from means front. Nath
  13. bellairaphon

    my home boiler issue again

    I'm just looking at the picture of your heating zoning set up. I'm just trying to figure out which one it is. Defo not S Y or W possibly a fully pumped c plan but the zone valve should be on the heating and the 2 pipes dropping down seem to be going to the cylinder? Nath
  14. bellairaphon

    Worcester 24i re-pressured but not firing

    Top of the boiler on the left hand side near the from. It will be stuck up if it's tripped. Push it in and it should fire up. Nath
  15. bellairaphon

    Banging pipes when a tap turned on.

    More than likely the shower is passing. How long has the shower been in? Nath
  16. bellairaphon

    Random boiler activity noises - Vaillant ecoTec pro 28

    Is the boiler hot and cold piped connected? Or just the heating and gas? Nath
  17. bellairaphon

    HOT TAP RUNNING HOT AND COLD

    Is there a model? Is it a private landlord and if so is it through an estate agents? If not then get in contact with your local council they can help in times like these.
  18. bellairaphon

    HOT TAP RUNNING HOT AND COLD

    What boiler do you have? Nath
  19. bellairaphon

    Vauxhall Astra 1.3 CDTi ecoFLEX 16v Exclusiv

    Hi John, thanks for replying. I removed the rear seat but I couldn't see anything apart from what looks to be a plastic section, not sure if it comes off tho. I will take a picture tomorrow mate.
  20. bellairaphon

    Vauxhall Astra 1.3 CDTi ecoFLEX 16v Exclusiv

    Hello, I'm after some advice on the named car. How will I get to the fuel sender unit? Reason been the fuel gauge isn't working. Thanks Nathan