  1. N

    Still getting air in C/H after chemical cleaning!!!!!!

    No obvious signs on joints/connections. Any thoughts were I should be looking?
  2. N

    Still getting air in C/H after chemical cleaning!!!!!!

    After talking to Myson they have suggested an automatic bleed valve - could that work ?
  3. N

    Still getting air in C/H after chemical cleaning!!!!!!

    Already tried this from a previous post - installation I believe is OK. I have explored this option previously hence the suggestion from Myson to increase 15mm feed pipe to 22mm
  4. N

    Still getting air in C/H after chemical cleaning!!!!!!

    I have a Potterton Prima 60F Central Heating system - simple heating system with 16 rads each with TVR so no room stat. Had problems with air in the system for a number of years. Changed the pump approx 6 months ago and since then get a kettling noise above the pump in the feed/expansion area...
  5. N

    Bled radiators but still gurgling

    It looks like the poster of the original question has gone away but I would be interested in the significance of this question
  6. N

    How to fit a 22mm slip coupler

    Not only have I got my question answered but I have received some soldering advice Many thanks
  7. N

    How to fit a 22mm slip coupler

    So any thoughts on holding in place on a vertical run prior to soldering
  8. N

    How to fit a 22mm slip coupler

    A slip coupler "slips" up and down the pipe so on a vertical section it will slip down the pipe while trying to solder - I guess
  9. N

    How to fit a 22mm slip coupler

    thanks for prompt response. My concern is holding the coupler in place as with a standard coupler there is a ridge in the middle which will hold the coupler in place
  10. N

    How to fit a 22mm slip coupler

    Will be cuuting out some pipe work in cold feed area of central heating system due to partial blockages. I have thought about using 22 mm slip couplers to ease reassembly. How should you keep the slip coupler in place on a vertical section prior to soldering ?
  11. N

    Stripping down painted copper pipes

    I have several 22mm copper pipes in my central heating system that I need to cut into to clean due to blockages. The pipes have previously been painted with what looks like a metallic paint or finish and are located in the airing cupboard. Any advice on removing the paint especially the part of...
  12. N

    Preparing painted copper pipes for reassembly

    I have several 22mm copper pipes in my central heating system that I need to cut into to clean due to blockages. The pipes have previously been painted with what looks like a metallic paint or finish and are located in the airing cupboard. Any advice on removing the paint especially the part of...
  13. N

    Kettling noise in feed/expansion pipes

    The system does not have a hot water circuit. I have a seperate Gas fired water heater.
  14. N

    Kettling noise in feed/expansion pipes

    I have a Potterton Prima 60F Central Heating system. Had problems with air in the system for a number of years. Changed the pump approx 4 months ago and since then get a kettling noise above the pump in the feed/expansion area after the system has been running for a couple of hours. I had been...
  15. N

    Options for curing a blockage in Feed expansion pipe

    I am pretty confident that it is draining becuase when I was draining the system I did not prop up the ballcock and the system was emptying quicker than it could fill.
  16. N

    Options for curing a blockage in Feed expansion pipe

    Rather than cut into pipe I was hoping to heat up the t connection and remove the pipework. Replace 15mm feed pipe with 22mm - replace leg to pump 2ft. Other pipe which is only 4" long, I was hoping to scrape out and leave in place. Does that sound like a good plan?
  17. N

    Options for curing a blockage in Feed expansion pipe

    I would prefer to use copper compression joints - not to worried about cosmetics. Could I remove old soldered T and re-use the pipe - will it clean? I didn't bale out the F&E first - that would have made sense I opened the drain on each downstairs radiator individually - draining and...
  18. N

    Options for curing a blockage in Feed expansion pipe

    I have a Potterton Prima 60F Central Heating system. Had problems with air in the system and a suspected flow problem in Feed/expansion pipes( magnet is attracted to the copper pipe junctions). Added Sentinol X400 3 weeks ago and the system ran a lot quieter with minimal air getting into the...
  19. N

    MYSON TRV stuck in high temperature mode

    Good call - I could easily rig up This has already been checked when added X400 I think I am sorted now - once again many thanks for all you time :lol:
  20. N

    MYSON TRV stuck in high temperature mode

    It is too hot to touch 2 feet above "t" connection. If there is a blockage would it be possible to connect a mains feed to vent pipe and reverse flush