  1. C

    Changing an electric shower 8.5kw to 8.5kw

    if a customer tells me it says 30amp then that's the rating, why on earth would someone look or even know what mA's it trips at, it seems to be you that hasn't got a clue & has been giving the OP some wrong info
  2. C

    Changing an electric shower 8.5kw to 8.5kw

    If the OP needs to ask these questions I'm not sure they would know the difference between 6mm & 10mm cable, They said 30amp rcd which i'm guessing is what is written on it & if it is then it's not big enough
  3. C

    Problem with Ideal boiler

    danfoss valves & an icos boiler, someone really did have it in for you didn't they :)
  4. C

    Moving boiler requires longer flue.

    I think we all know the answer to that one
  5. C

    Changing an electric shower 8.5kw to 8.5kw

    a 30a rcd wasn't big enough for the old one & it still isn't big enough for the new one shame on some of you for missing that :roll:
  6. C

    Boiler humming but no flame - our possible suspects..

    i hope you have an open vented cylinder & not an unvented one ?
  7. C

    BSP shower connection - just loads of PTFE?

    they won't work, the bit that fits inside the tap tail won't fit inside those off set shower fittings
  8. C

    Combi or unvented - based on my property

    sorry to disagree with some, but @ 13 ltrs/min i wouldn't consider a combi or unvented
  9. C

    Porcelenosa shower valve spares

    is that why he has to bend over :D
  10. C

    ID These Please....?

    as dia said paste on it's own won't seal the thread
  11. C

    Plugging the Oven In.

    as others have said a completely crap gas installation back plate elbow not screwed to the wall back plate elbow in totally the wrong place (look at your MI it will tell you were it should be. suspect use of ptfe tape no bracket or chain no Mr Green it's doesn't need an isolator tap...
  12. C

    TRVs versus Room Thermostat

    FFS why has this thread turned into such a complicated one OP your plumber is an idiot to comply with everything & save energy all you needed to do was exactly what you have except the hall rad (where the room stat is) shouldn't have a trv fitted, so either remove the trv from the hall &...
  13. C

    System Loop & Pressure Indicator

    OP has already been told this but obv didn't believe it the first time. 45, Putting a boiler in the loft is the Devils work. they have been told that to
  14. C

    Heat exchanger on Baxi Combi 105 HE

    I'm betting on evens that there is another post on here over the weekend about the plate hex leaking after being soaked in brick acid :roll: oh & OP don't forget 1.0 bar this time not 2 bar :wink:
  15. C

    Water softener feeds

    the hoses supplied won't be 22mm internal :wink:
  16. C

    Which unvented indirect cylinder to buy?

    I think you misunderstood me, I wasn't saying anyone shouldn't find out info, but it is always wise to get the opinion of a professional who will be able to answer alot of questions, for example have you had the flow & pressure tested on the incoming cold main ? because the OP may find that...
  17. C

    Which unvented indirect cylinder to buy?

    because they are asking questions on here that would be easily answerable by getting the installer around for a quote, then they are better informed & won't need to ask questions about things that at the mo they have no idea about, plus the questions being asked leads me to believe that the OP...
  18. C

    Which unvented indirect cylinder to buy?

    why don't you ask the installer with the G3 cert that you HAVE to use what his recommendations are
  19. C

    Unsecured turret - Boiler at risk

    tbh i think you are lucky you got away with AR looking at those stains i'd be capping off the boiler
  20. C

    Ball cock cycles after filling - why

    no idea Dan but it might help if the OP had fitted the right ballvalve :roll: