Search results

  1. C

    New Taps - Different fittings. Which adapter do i need?

    yes you could use those (don't forget to get an insert to go inside the pipe before you push them on) plus you shouldn't use a hacksaw to cut the pipe as this will leave burrs which unless you file them off will damage the "o" ring inside the fitting, you would be better getting two service...
  2. C

    System boiler enough for my house?

    Tony, they have had two quotes for a WB
  3. C

    Can hear water running in pipes---can I prevent it

    you sure it's not the water in the waste pipes you can hear ?
  4. C

    Illegal gas installer prosecuted !

    & they sometimes sell bags of coal out the back of their vans
  5. C

    System boiler enough for my house?

    It's not just WB it's any boiler with a ally hex, it's just that WB have their heads so far up their backsides that they can't see they should change to stainless
  6. C

    System boiler enough for my house?

    OP if you get a water softner then a hard water supply must be connected to the boiler/heating system, you CANNOT feed a WB from the sofened side. The system must be flushed either a manual flush using chemicals or a powerflush, a WB hex does not like any debris in the system, anyway if it's...
  7. C

    Flue change on combi boiler due to extension, issues!

    I doubt very much if a vertical flue will be giving your neighbour nuisance fumes, these are associated with normal flues blowing over the property boundary so i doubt if BC or GS will be bothered about this. vert flue shouldn't be within 600mm of either the top or either side or 2m below a...
  8. C

    System boiler enough for my house?

    If you have good mains pressure and flow, go for the largest ATAG two-bathroom combi boiler which will eliminate space consuming and needless silly cylinders. A quality product. About the best. Be sure to fit combined flow regulators/isolation valves on all the hot and cold outlets to balance...
  9. C

    System boiler enough for my house?

    You must hold the G3 cert to be able to fit unvented cylinders, make sure you check anyone that quotes. I would forget about this guy for starters, 1. megaflows are overpriced 2. he's suggesting a ideal boiler 3. he's talking about changing it to fully pumped (which is fine) but he is...
  10. C

    15mm female to female?

    I'd still like to know why the OP needs a female end for a tap :?: just out of interest
  11. C

    Multiculturalism in the UK

    i wonder why it was described as a terror attack & not a race attack ? maybe because in this country you can only be a racist if you are white
  12. C

    A sign of things to come.

    I can't say i've ever agreed with joe, but this time he's right, time to shut the door before all these benefit scrounging ****** get over here
  13. C

    Conventional boiler.... comeback Combi all is forgiven!

    wow 8 pages just to find out Tellme is a **** :shock:
  14. C

    Calling all Remeha experts.

    where is the pump wired to ?
  15. C

    How to stop a copper pipe turning in the wall?

    yes of course silly me & there i was thinking putting an outside drain off was suppose to make things easier, i'm sure there aren't any customers that mind having a trap in their laminate or tiled floor, or having to have their very expensive carpet pulled up, providing it's lagged under the...
  16. C

    How to stop a copper pipe turning in the wall?

    I thought we were talking about a heating drain off not a outside tap, or do you want to take the floor up every time you wanna drain down :roll:
  17. C

    How to stop a copper pipe turning in the wall?

    just put a plant pot in front of it if you are worried about the kids touching it, it's a drain off for the heating, why are you worried that someone may not hold it while using it, it's only likely to be used once every 10 yrs
  18. C

    Standard measures

    any advance on 37 ? going once, going twice...............................
  19. C

    Standard measures

    where do you buy 18mm copper from ? I think it's 35mm
  20. C

    Type of sleeving for a gas pipe passing through a wall

    now you all know what the sledge hammer is for in the back of my van :wink: