  1. C

    Megaflo with Potterton Suprema

    is that because he doesn't know ? if you are proposing to get him to fit the unvented cylinder i hope you have checked he has the G3 cert ? but to answer your question yes any fully pumped heat only boiler can be used with an unvented cylinder i would also be looking at a diff cylinder...
  2. C

    Type of sleeving for a gas pipe passing through a wall

    it doesn't have to be metal it can be plastic, I normally use waste pipe, the sleeve is more there to prevent a leak inside the wall filling the cavity which is why it's sealed on the inside only & to stop the copper from corrosion your installer is wrong in saying it must be metal, although...
  3. C

    Found a gas pipe.....

    & neither is a push fit cap (which I guess is what you mean as you said rubber olive) it needs to either be a compression cap or a soldered cap both of course providing it's still connected to the gas supply, as above it might be dead which is why it's moving around
  4. C

    Should I complain about this CH plumber? Is it safe?

    I don't care if he's young or old that work is as ruff as a badgers arse, as others have said stop the chq, deduct the cost of repairs ie new carpets where he has damaged them either through solder, water or inhibitor & phone gas safe & get an inspection done ASAP. what on earth was he using...
  5. C

    Can I remove the wall thermostat from the heating system?

    just replace the stat thats there with another honeywell, they are less than £20 why are you trying to over complicate things & yes the building regs req a room stat
  6. C

    gas metre in garage conversion

    I'm slightly confused, are you talking about a garage that is along side the house, you said a garage conversion so why are you talking about having a shell built ?
  7. C

    New 2nd hand boiler

    I just love that he wants £149-99 for an old NEC mobile phone that doesn't work with no charger :lol:
  8. C

    Pressure on boiler drops, laminate floor bubbling

    not if they are boxed using plasterboard & skimmed, i would certainly prefer that option to beating up the concrete & replacing the floor every 6 months, copper in screed will be knackered (all of it) if it isn't protected so repairing a leak is a complete waste of time & money
  9. C

    holes for plastic pipe through joists

    I use 20mm for 15mm & 25mm for 22mm, but do a search (or someone might have a link) because there are distances for drilling a joist
  10. C

    Pressure on boiler drops, laminate floor bubbling

    forget about the pipes under the floor if they are leaking, run new drops to each of the rads from the roof, i don't know why the first plumber didn't suggest this
  11. C

    Warm radiators in the summer

    as ss said it sounds like the pipework has been installed incorrectly, cylinder ret should always be the last connection before the boiler
  12. C

    can t get access to the combustion chamber

    maybe you are banned :lol:
  13. C

    Advise/help needed with poor water pressure

    no probs two answers are better than none :wink:
  14. C

    Advise/help needed with poor water pressure

    it should be serviced every year by someone with the G3 cert
  15. C

    No hot water from Megaflow

    as above & i wouldn't get this numpty to test it, i think he should just stick to changing your tap washers in future
  16. C

    Unnecessary damage caused by plumber in search of leak

    my 5p worth, charging £80 p/h constantly is wrong, most trades give a discount after the first hr, i know we only have one side of the story (but i have no reason to disbelieve the OP), personally if i couldn't find the leak then i would have charged for the first hr & no more, i would have also...
  17. C

    radiator valve drain off

    you will have drops to every rad downstairs so if you only fit one then it will only drain that rad & the ones upstairs leaving the other 3 rads & their pipework downstairs still full, change all the locksheild rad valves downstairs for ones with built in drain offs
  18. C

    Replacing lead supply pipe; does boiler need adjustment?

    I think you have already sussed that answer :wink:
  19. C

    Flexible pipes and push-fit pipes

    Oh dear I hope he doesn't get upset & make me call him a ******** (cheers DM)
  20. C

    Flexible pipes and push-fit pipes

    because unless the conservatory rad is connected via a zone valve & a room stat then this is against the building regs, you aren't allowed to just connect onto the existing system any longer