  1. J

    LIMs/Schedules of Inspections

    when you go to the db take switches off, etc you can see what cables are used, and see if they have any 'Cables incorporating earthed armour or sheath, or run within an earthed wiring system or otherwise protected against nails, screws etc... '. also when you take of switches/sockets you...
  2. J

    3 Core SWA earthing

    If possible I allways bond the banjos at both ends
  3. J

    Potterton Profile 40e

    I know it proberly won't help you but they were made between 1988 and 2001. My dad used to work at the factory where they were made.
  4. J

    Replacing Pull Switches

    check how many terminals you have at each switch, old and new, your old switches if they have four terminals might be double pole switches, if your new switches have three terminals, they mght be two way switches.
  5. J

    2 plate wiring advice needed..........

    dont fit 12v ELV downlights just stick to pendants.
  6. J

    All RCBO consumer unit

    Dont use the mem rcbo/pods then, I have a mem db with rcbo/pods at my house, they are a pain to clip on to the busbar/dinrail and then you have to put the lives and neutrals in.
  7. J

    Hager's current line of domestic consumer units.

    I think I must have fitted the installer configurable one, yes it was a pain
  8. J

    Hager's current line of domestic consumer units.

    I thought you could remove the mcbs without taking the busbar out. I know with the wylex dbs you have to remove the busbar to get the mcb.
  9. J

    Idle question about TNCS systems

    With any luck if the neutal has broken from the cable the live would have broke too and the REC fuse would have blown
  10. J

    Under floor heating

    If you have central heating in your house I would not bother with under floor heating, just get a bigger radiator or get 2 radiators if need be. In the kitchen we have a plinth htr with works with the boiler and blows out the hot air.
  11. J

    Is 'Steeple' a viable brand for consumer units?

    I have used both wylex and steeple dbs both are good d/bs. I would not mind having the steeple one in my house.
  12. J

    Is 'Steeple' a viable brand for consumer units?

    Im think that steeple DBs are made by the people who make wylex.
  13. J

    Memera 2000 rcbo

    I think you can still buy rcbo pods for memra 2000 fuseboards, part no MR30 but you will need a 40a mcb. They £50 ish
  14. J

    Best Bathroom Fan

    I think vent axia are good, they make fans for manrose, so I have been told, Ive got a timer silhouette in mine
  15. J

    RCD tripping on high power appliances

    I had a mem rcbo pod trip out when an iron was switched on, was due to a fautly pod
  16. J

    The history of the fusebox?

    Ive been told that electricians were joiners from back in the day, hence the timber trunking you used to see
  17. J

    8 way grid plate and back box

    I hope the guy knows he has to fit fuse module too with all the DP switches
  18. J

    Mould on Bedroom Celing - HELP :(

    I had the same problem two years ago, caused by the lack of insulation in on part of the loft.
  19. J

    Replacing T&E cable that feeds an outside light

    I thought fp was good to be used outdoors. i will ask the tutor at my next 17th ed class
  20. J

    Replacing T&E cable that feeds an outside light

    use a piece of fp, i know it is expensive but it does the trick!!