    Ring final in conduit

    That might depend if you don`t mind being plunged in to darkness ? Are going the have LED emergency lights with an automatic back up supply ? What`s your location ? (although power supply can fail anywhere) ?
  2. E

    Bathroom extractor fan.....cost?

    Yes ok, but I was going on the safety side with 12 v. also the cost / price choice for IPX4 or IPX5 is not that good. Still reckon that a transformer next to the isolator makes for a safe & neat job. Showers are usually on RCD / RCBO. Circuits for lights / Fans are often not.
  3. E

    Bathroom extractor fan.....cost?

    Hi Actiongirl, If installed in zone 1 (best place to remove the steam) it must be 12 volt and the transformer should have 3 pole isolation outside the bathroom. Core drilling the wall, wiring isolator and installing fan circa. £200 + £70 if a ladder needed for fixing outside grill. It could...
  4. E

    electric fan heater into my bathroom

    In bathroom fit an RCD or RCBO in consumer unit. FCU or local isolator should be outside of bathroom. Fan Heater must not be fitted in zone 1
  5. E

    How I have reduced my energy bills.

    With all the news of energy costs I thought I should share what I fitted over a year ago. I installed a bran new Air Source Heat Pump with an output of 15 Kw in 2012. It`s working brilliant my whole house has been so cosy, a 4 bed semi & attic conversion, with a 6 Mtr UHF conservatory and...
  6. E

    what electric water heater?

    Something like this, maybe? :shock: 9.5 Kw ? may satisfy your needs :) not so ECO despite having eco in its name, that will buzz the meter with a high leccy bill :x I will carry on with my solar, my hybrid heat pump and low energy costs. :wink:
  7. E

    what electric water heater?

    We would really need to know how many people need to take a shower ? I could say a standard cylinder could supply the needs you mention above. If your needs are for more people, then an electric 8.5 kw shower may be a better solution, can your supply provide a 40 Amp circuit, if not then...
  8. E

    curiosity question - heating zone valves

    Yes Steve I have had similar views for over 30 years so I wired multiple Honeywell 4043`s controlled from properly sited room stats, fed from my programmer. All the zone stat "call" SL`s are wired via the brown to open the relevant zone valve x 6. All 6 grey micro switches are fed from the 3A /...
  9. E

    Keeping Koi

    Yes I keep Koi, it dose`nt have to cost so much, if you do it DIY Planned it, built it, on the cheap, lot of effort digging down for a 6ft bottom drain, gravity fed filter, Airlift pump return, Heated by ASHeatPump, My Koi are beautiful, pampered and contented. In total I have about 50 fish in...