  1. T

    Immersion Tank keeps overflowing

    Is it the type that has a small tank built in above the hot water cylinder ?
  2. T

    Help my new toilet is leaking!

    Is it ok when the lid is off? If so adjust the flush button as may be holding it open
  3. T

    Help my new toilet is leaking!

    Make / model ? Is there anything getting in the way of the flush flap washer? or a fault in the rubber of the flap or a bit of poorly trimmed plastic on the seat where the flap seals against
  4. T

    measuring manky radiators and replacing

    Old rads probably corroded internally anyway
  5. T

    banging/juddering toilet

    You could put a couple of small dabs of silicone between wall and cistern as an easy fix (so you dont have to touch the water side of things) Try holding cistern against the wall before hand just to see if it is a securing problem. Only use a small amount of silicone otherwise you will...
  6. T

    measuring manky radiators and replacing

    The question regarding this "standard" radiator ..it is likely to be an imperial measurement,not the now standard Metric.
  7. T

    measuring manky radiators and replacing

    1200 with rad extensions,newer 1/2" valves and pegler type extensions look best. As for "off the wall" pipe measurements (wall to centre of pipe) different brands have different sizes If you post this measurement someone will know what rad suits best
  8. T

    ideal classic he12 vs ideal icos he12 boiler

    Also if the HE version is actually new...how can you tell if it will be ok in a couple of years? It is an unknown
  9. T

    sooty deposits in hot water

    Is it bits of rust (very dark red/brown)? If it is ,could be old iron barrel pipework going to bath taps.
  10. T

    Megaflow early version pressure relief dripping

    One i looked at today (HE) was a 10 bar relief
  11. T

    bathroom has no separate stop cock

    POWER SAW !!!!! :x dont use power saw on copper..its way too soft and will probably mangle it up
  12. T

    fitting new radiator in bathroom - match up length ?

    If the pipe CENTRES (not the gap between the valves) are 560 .. A 600 towel rail may actually fit, as 600 is the total width The pipes enter the towel rail normally 15-20mm from the edge of the rail times 2 thats 30 -40mm My 450 towel rail has centres of 420 :) There are some valves that...
  13. T

    Megaflow early version pressure relief dripping

    10 bar.. pretty sure thats the same...going to a house tomorrow that has new megaflow i will look then :)
  14. T

    Loud oscillations from Ariston combi boiler - please help

    Just wait till he comes to sell the house using these new sellers packs An unregistered boiler hmmmmm... God help him if theres a gas leak :( Im not Corgi , I fitted my own boiler ,and got a Corgi to commision it (admittedly I used to work for him so he knows my capability) He was there to...
  15. T

    Leaking Kitchen Mixer Tap

    Could be leaking from anywhere really...even under sink.. Do you mean it is dripping from the spout? If so is it a 1/4 turn tap (ceramic disc) Or is it a turn lots of rotations (tap washer and probable reseat) :)
  16. T

    Megaflow early version pressure relief dripping

    Not had much to do with the earlier ones.. Is the valve replaceable with a newer version ?
  17. T

    Boiler losing heat

    A decent plumbers merchant will sell them. I had experience of a DD megaflow last year where the water would only get slightly lukewarm Eventually i found there was a leak in the Kitchen area (It was a Pub)couldnt hear the water running. I tried replacing the lower Immersion heater before i...
  18. T

    Central Heating Problem

    Had one like this recently where a rad was fitted in series on a one pipe system. I capped it off and guess what heating didnt work On further investigation i worked out it was 1 pipe and had been added on and the old house owner probably was told not to turn it off :( Looped it back in and...
  19. T

    Megaflow early version pressure relief dripping

    Been to look at an earlyish Megaflow Its the one where the pressure relief valve has a bent metal "arm" (instead of the usual plastic knob) as the manual release. The customer has noticed intermittant dripping into the tundish.. I carried out the usual ,open hot tap...open relief valve and...
  20. T

    TRV

    Flow
Back