  1. T

    cool rad

    If the valve isnt open on fill up it wont fill all the system.
  2. T

    Partial blockage in central heating pipe

    Pump the best place as most flow. Will connect instead of a radiator though.
  3. T

    Rad advice please

    If a rad has recently been changed there could have still been some air in the system from when this procedure was carried out.
  4. T

    Megaflow airgap and water running ?

    As it stops after a few seconds,is it just the pressure valve reaching pressure? This sounds a bit like bus doors :) and tapers off till silent,lasting no more than about 10 seconds
  5. T

    RAVENHEAT CSI 85 COMBI BOILER, PRESSURE KEEPS DROPPING?

    It could be the pressure relief valve,however if it isnt always leaking from discharge pipe it could be an expansion problem Has the expansion vessel got the correct pressure in it when the heating pressure is released.Cant think what you call this pressure basically the vessel is pre-charged...
  6. T

    Prima F50 Problem, Lack of sparks?

    These were fixed by resoldering the 6 connections under the board...but you state these look ok What i noticed on the ones i`ve done was a hairline crack around some of these solder "blobs" . they are not very obvious cracks,a magnafine glass would help. I have also fixed a couple and put them...
  7. T

    Which size spirit levels are the most useful for GP use?

    600mm and 1200mm is what i carry. got a pocket 10 incher too :)
  8. T

    what is best sds drill and masonary bits for under a ton?

    I gave my Bosch SDS drill hell for 5 years till the SDS part stopped working. I bought another Bosch as its replacement.....enough said :) They are for sale under £100 these days
  9. T

    Feather edge fence,what treatment?

    Hello , I have a feather edge style fence (close board) which has not been stained yet Its been in for 4 yrs . Can anyone recommend a CLEAR coating that can be applied ? Thanks, Tim
  10. T

    Worcester 24i :(

    If the fan motor has gone no amount of WD40 will help :( Should really be done by a heating engineer but we are on a Diy site !
  11. T

    Low pressure in Vaillant ecotec plus (NOT combi)

    You will need a filling loop to pressurise the system as this too seems to have been omitted :(
  12. T

    Low pressure in Vaillant ecotec plus (NOT combi)

    Basically you need to cap off .. The vent pipe (the one that goes over the top of the tank and in) The cold feed to CH that comes from the lower part of the tank(which may join the vent at some point) The main feed to the F&E (little tank) ball valve. The chap who fitted it all should do it...
  13. T

    Prima F50 Problem, Lack of sparks?

    You took the pcb out to look at the solder joins right? I carry a couple of these boards ,that had this fault,that i have fixed so it must be a fairly common thing. You have checked the fuse on the pcb ? Could you post the pcb part number ? just to see which one it is,thanks
  14. T

    Overflow Pipe in Cold Water Tank Leaking

    Any chance of a picture? Sounds like a leak but cant picture this layout
  15. T

    Overflow Pipe in Cold Water Tank Leaking

    The over flow pipe must come out near the top. Any other pipes in the tank must be.. 1. The main feed TO the tank 2. A feed from the tank to the water system Ie cold and hot taps .
  16. T

    Garden tap advice

    Use a foam lagging or armourflex where the pipe is showing and preferably a few inches under ground just in case. Underground it should be ok,dig as low as you can be bothered to. I`d say a coulpe of feet down if likely to be dug near (ie flowerbed)
  17. T

    Potterton Netaheat 16-22

    When i said reset i meant to turn the programmer off then on again :) If the fan comes on but nowt else does look like a pressure fault id say. Although if its testing for pressure in the case ,wont it usually turn the fan off after its done its failed sequence?
  18. T

    Prima F50 Problem, Lack of sparks?

    The buzzing...could it be the noise of sparks trying to make a contact? I did have one that was arcing and making a buzzing sound.just a thought.
  19. T

    Lukewarm radiators - New boiler needed?

    If its adjustable put the pump on full (you probably already done this) You can get 2 types of X400..in a bottle or in a tube that goes in a "silicone" gun. The gun one can be put in a rad bleed The bottle can also be put in same area if newish style rad if you isolate the rad and drain some...
  20. T

    Low pressure in Vaillant ecotec plus (NOT combi)

    My 618i is heat only boiler ie not a combi :) Its the 800 series that are combis