  1. T

    Neon Screwdriver

    Imagine this - the case of a metal CU is live due to schaffed cables entering a non - grommeted hole. I test with my neon screwdriver and it shows a voltage present. I test with a two leaded tester between the case and what I think is a good earth and it shows nothing because this earth is also...
  2. T

    Voltage and ampage - Is this correct?

    Yes, tap them smartly across the head with it....................
  3. T

    Adding a small consumer unit

    Mudsis, I agree - you certainly do not give any advice. No point in you being here then. Bye
  4. T

    Adding a small consumer unit

    Dimuss, Please publish your full name, address and qualifications on this forum. Thanks
  5. T

    Quick motor question...

    Use the higher figure for your calcs being as it is the power taken by the motor. The lower figure is the useful work the motor can provide.
  6. T

    3 core lighting puzzle

    May have been part of an old two way switching system - how long have you lived in this house - are you aware of any alterations that made the need for a possible, alternative switch redundant? Or, perhaps there is another swicth that you have not yet discovered - what about in the attic? Or...
  7. T

    Ye Gods!

    That is dreadful BAS - they should have used a proper cable grip................
  8. T

    High integrity earthing

    Adam, Without quoting reg numbers these are saying that a high integrity CPC shall be one or more of: (a) 10mm single if not mechanically protected (b) 4mm single if mechanically protected (c) made up of dual CPC's whether that be cable and conduit, cable and armour braiding or two...
  9. T

    High integrity earthing

    Softus, I am not quite sure whether there is a contradiction but, because I cannot tell, probably means that the original regulations were not worded clearly and probably expalains the difficulties that we have seen here. I think that the only area of ambiguity is when picking the csa of...
  10. T

    Help! im getting electric current when i have a bath

    When I visit my Auntie how heavy is my parrot?
  11. T

    High integrity earthing

    Thripster, Softus didn't miss the pre-amble - so sorry Softus.
  12. T

    High integrity earthing

    Softus wrote:- 'But the 16th Edition also says this: 607-03-01 ...the circuit shall be provided with a high integrity protective conductor connection complying with the requirements of Regulations 607-02 and 607-04. The following arrangements of the final circuit are acceptable...
  13. T

    High integrity earthing

    Whether it is the 16th or 17th the following applies (17th nomenclature):- 543.7.1.3 The wiring of every final circuit and distribution circuit intended to supply one or more items of equipment , such that the total CPC current is likely to exceeed 10mA, shall have a high integrity...
  14. T

    High integrity earthing

    17th - not word for word but might help 543.7.1.3 The wiring of every final circuit and distribution circuit intended to supply one or more items of equipment , such that the total CPC current is likely to exceeed 10mA, shall have a high integrity protective connection complying with one...
  15. T

    Earthing a chrome light switch?

    it's behind you................................... It will be where the mains supply comes into the house. You should see (if you are lucky) a chromed looking main earth terminal with a number of green and yellow wires coming from it. However, if you feel that this is beyond you I would...
  16. T

    High integrity earthing

    To NotHimAgain, If a circuit has a node, does that mean it will only pass current in one direction? Yours Hugh Janus
  17. T

    ottermill system t 45a mcb

    Have a look on Ebay - you might well be lucky.
  18. T

    Can you use a electric insulation cert

    No, he needs a Parsimonious Insultation Repartee.
  19. T

    Kitchen wiring question

    A. Next Tuesday, half a crown and thruppence. Find out the power rating(s) for the cooker.
  20. T

    Kitchen wiring question

    A quick search on the web shows this to be a double oven requiring to be hard wired in. What is the power rating for this cooker? Of course you know about the Part P implications?