Search results

  1. J

    new running machine trips RCD

    Agreed and have a test carried on the RCD, if inconclusive. Agreed. The 100mA RCD is fitted for overall fire protection to property etc: and doesn't give personnel protection; hence the 30mA unit for sockets - most important where a portable running machine is concerned.
  2. J

    Wax dots on fuse?

  3. J

    Wylex Fuse box

    And did you uprate the cable to your shower as well? Jaymack
  4. J

    Transformer calc

    If the transformers were in parallel, unlikely due to the difference in the pu values of impedance, and the feeders are from a common bus after the tfrs: - Fault Level Source = 0.050pu. Fault Level Transformer = 0.050 + (0.15 × 0.30)/0.45 = 0.1pu. Fault Level Feeder 1 = 0.50 + 0.1 + 0.05 =...
  5. J

    PFC

    You appear to be confused with "Execution" and Electricution which may or may not result in a fatality. Jaymack
  6. J

    MCB &RCD's

    Powerful? What means this? :P RCD required, see regs 471-08 and 471-16. Not required to the regulations, although some suppliers require it, installer's option whether to install or not. (CYA by suppliers). Jaymack
  7. J

    Strange RCD tripping problem.

    A loose connection downstream of an RCD, may cause it to operate due to transient voltages or capacitive effects. Jaymack
  8. J

    Light circuit tripping RCD

    What are your supply characteristics? is it a TT system with an RCD; say time delayed, 100mA rating as the mainswitch on the DB; and a further RCD, say 30mA rating for sockets etc? Alternatively if you can't answer this, can you post a picture of your supply meter intake position?. Normally an...
  9. J

    ceiling rose with hook

    Are you fitting this to the wall? :lol: I think what you need is a junction box with terminals fitted inside: - http://www.screwfix.com/app/sfd/sea/searchresults.jsp;jsessionid=KS5HYTCQXSSTICSTHZPCFEY?_dyncharset=UTF-8&howMany=15&searchText=chocbox&x=15&y=13 This can be pushed up...
  10. J

    optima compact 6

    The engineering information (installation manual), that I have states: - "To reset panel to factory reset conditions". Within 5 seconds of powering up the panel, press reset, reset and sounder should bleep in panel. The telephone number for help is 08448000235/260. I think the first...
  11. J

    wall cable problem

    Apart from the difficulty in access, how do you propose to support the vertical cable, at the required intervals to the regulations? Jaymack
  12. J

    Extractor fan vents banging

    There are already fans on the market with solenoid operated grilles, these only open when the fan is energised. You probably know that. Jaymack
  13. J

    Extractor fan vents banging

    This would increase the air resistance of the fan; and reduce the efficiency: - less air flow! Jaymack
  14. J

    Extractor fan vents banging

    You could try an external fan cowl type, these also have either self-closing slats or a flap; and come in white or brown. B&Q and Homebase etc. sell these. Jaymack
  15. J

    cooker hood

    I wouldn't recommend using a fan as a substitute for a cooker hood. there will be a build up of grease etc., on the motor and blades. This has been the cause of at least two fires, in my experience. Jaymack
  16. J

    MAX DEMAND LOAD

    The method of calculation of diversity as found in the OSG is very conservative. In reality the maximum demand is far lower than this. If you really want to know, put a recording clamp meter on the tails. I would guess that most installations peak at around 30-40 amps. The only exception...
  17. J

    kitchen extractor

    But don't ever use an extractor fan in lieu of a cooker hood. I have seen at least one fire; where the buildup of grease caused a major fire. Jaymack
  18. J

    Qualifications to perform PIRs

    Anyone can do a PIR, even joe public; but a problem probably arises when the report is passed to an insurer, they may require the person carrying out the test, to be registered with a body such as NAPIT etc. The NICEIC only allow approved contractors to do these reports, not simply the...
  19. J

    Help from a sparky please Tripping of RCD

    Is your shower neutral connected to the rcd section of the bar? If not i.e. it is connected to the non-RCD neutral bar and the phase is connected to the RCD side, this will cause the RCD to trip on switch on. Jaymack
  20. J

    Hoods on downlights

    Don't use fire hoods. They are near impossible to fit properly and can become dislodged. Use fire and acoustic rated downlights - these are enclosed in a vented canister and fitted with intumescent material that will activate in the event of fire, much like fire door seals. If a penetration...