    Programmer wiring advice please!

    I'd have another look if I were you :wink: although the new programmer will replace the old one,the wiring of the terminals is not the same
  6. M

    2 Pump Non Vented System Help Please

    Yes I'd say it was a secondary return for sure, how big is your property? you may or may not need/req it, try turning it off and see how you get on without it if you find that you don't want it then disconnect it and its associated pipe work also Matt ps the thermostat is inside the...
  7. M

    baxi expansion vessel attached to wall????

    No not really,but the op need not worry,his engineer has probably sited it correctly on the return Matt
  8. M

    24v Zone Valve?

    Are you using a spare zone on the manifold? If so you will be able to get a 24v actuator from your local parts centre These for example are 24v ac/dc http://www.myson.co.uk/underfloor_heating_controls.asp
  9. M

    3 port valve actuator

    In which case the rads would get hot when the hot water is in demand would they not? Think about it
  10. M

    3 port valve actuator

    In which case he would still likely have one or the other! (not necessarily with proper control though) the valve can't inhibit HW demand :wink: The op needs to clarify, whether he has a) hot water but no heating b) heating but no hot water c) neither d) both, but uncontrollable...
  11. M

    Wiring for Drayton ZA5 Zone Valve Actuator

    If true then I despair :shock:
  12. M

    Three port diverter problem

    I know what they are supposed to be DH, what I meant was, I have never seen a 3 core & earth cable containing 2 yellow cores, same as I have never come across a 3 core flex containing brown,green/yellow and green cores :wink: Matt
  13. M

    Three port valve not the answer

    Sounds to me like the second microswitch inside the actuator is permanently closed. Take the orange out of the wiring centre and make it safe, now select hotwater ,has the valve stopped motoring? if so the actuator is faulty. Matt
  14. M

    Three port diverter problem

    Do you know when I said I'll have seen worse?........ :shock: seriously though, thanks for the pic, as it now puts a different slant on things. The actual problem could lie within that wiring centre i.e a damaged pcb track Identifying the cables will be a good place to start. Matt
  15. M

    HW OFF in Y-plan system with additional relay?

    Do you mean how do you connect a relay to give a hot water off connection?
  16. M

    Three port diverter problem

    Howard both of the above quotes suggest that the valve has motored which also means that there has to have been power on the white the white is ultimately connected to the central heating on terminal which you are now saying does not have power......... Matt
  17. M

    Megaflo wiring issues.

    This is easily done I will direct you but first answer the following do you have a common supply to both appliances? ie one power source for both? if so is the supply to the boiler or cylinder first Matt Edit- basically what Dan says (these younguns are to quick for me :wink: ) still...
  18. M

    help with identifying part

    no probs Jim, to answer your questions 1)How long is a piece of string? if your question is could that manifold incorporate one then yes 2) yes, if you have access then try it again and see if the hotwater tracks back right along the cold inlet There's nothing wrong with it. get him...
  19. M

    Three port diverter problem

    It doesn't matter I will have seen worse mate,post one anyway