  1. S

    bloody 1 way light switch

    Not necessarily Ricicle, has the the switch got a Common terminal?? if so by connecting to l1 and l2 nothing will happen. or maybe as ricicle says its a two way switch and your trying to replace it with a 1 way . Nick
  2. S

    Looking for a firm for a substantial project in Manchester

    push to make switch to open door perhaps?? or just a badly terminated 1 way switch Nick
  3. S

    can i install a 50w cooker into standard plug socket?

    Follow the link below and looking at the instruction booklet says the rating of the oven is 1950W, but the four rings total another 5800W so unfortunateley a 30A supply is the only way to go. Nick http://www.indesit.co.uk/indesit/productsheet.do?productId=34924UK
  4. S

    P.P reinforcement fibre matting for traditional screeding

    Are you sure its actually a matting? I have seen used before chopped polypropelene strands used in screed as reinforcement, this is more likeley what they are asking for . Nick
  5. S

    Installing floorbox, power and networking

    No we do not call out a structural engineer every time we drill a joist as we should know the rule of thumb when drilling joists ie within the first and third portions of the joist and as near dead central as possible of the total depth , steels have a totally different set of rules and if you...
  6. S

    Installing floorbox, power and networking

    Drilling holes in structural steels is not to be advised unless you have the positions confirmed by a structural engineer. It may be like drilling a hole in a wooden joist but the consequences can be a lot more serious if a steel beam fails .I hope your public liability insurance is upto date.
  7. S

    Installing floorbox, power and networking

    "Have had to drill holes in steel ", WHOA There, i hope this steel is not a structural member??? That may have been why the cable was run over the top of it. How thick was this steel you have drilled ?? doesnt sound good to me
  8. S

    RCBO Neutral lead - to cut down or not cut down?

    I always shorten them both and replace the ends with a bootlace ferrule of the appropriate size,and do nogt forget to mark the white core with some earth sleeve as it is a fuctional earth should be identified as such. Nick
  9. S

    V guide for exakt precision saw

    anyone know where i can get one of thes on its own.i have the saw and the newr ones come with it , but the exakt site is down and googling comes up with nothing . i need it to cut some pipes squarely thanks Nick
  10. S

    Trade nicknames

    I called the bloke on site fitting the copper pipes for a new food prep area the other day plumber and he was most upset he insisted he is a pipefitter LoL Us electricians still get the usual sparks sparky flashbang!!! LoL
  11. S

    3 Pirs activating lighting

    Sorry to hear that mate, recession i guess biting hard?? Where did you work ? Nick
  12. S

    3 Pirs activating lighting

    maybe so coljack but if you could redraw your drawing showing the switch and perhaps show it wired both ways it would clarify it for the OP, I dont want to have a o at altering it incase i mess the drawing up. Nick
  13. S

    3 Pirs activating lighting

    The only thing with your drawing ColJack is your assuming the feed is at the switch, it may be at the first light as in my example, yours is another way to do it but depends on the actual situation on site. Nick
  14. S

    3 Pirs activating lighting

    If the PIR requires a neutral conection then wire a 3core and earth cable between the three PIR sensors then back to the first light, the connections can all be made at the first light so there will be 3 T+E and 1 3c+e at this point, T+E 1 = LIVE AND NEUTRAL FEED T+E 2 = LIVE AND SWITCHED...
  15. S

    drainige pipe adaptor

    Thats the problem i am havingit sburied in concrete at the top of the bend on the drain, i have had a piece of the old drain out to measure its diameter it was approx 135mm which i had confirmed is the old hepsleve thick walled clay pipe not the newer supersleve thin walled pipe.I know i could...
  16. S

    drainige pipe adaptor

    Picture not possible as camera broken, i know the mcalpine one would probably do the job, but i am trying not to reduce the dia of the pipe too much. That is the problem i had that the number Hepworth gave me does not seem to exist. the problem is i have half of an existing black plastic coupler...
  17. S

    drainige pipe adaptor

    Hi again, well what awek that has been, as i am working in a prison no contact withe the outside world. My emails to hepworth bounce, tried emailing wavin asn they now own them, and got the part number to an osma adaptor which is not for my pipe , get back to them and tell them its clay pipes i...
  18. S

    Grommets...!!!!!!!

    Besa box lid and couple of M4 brass nuts and bolts do the job admirably. Nick
  19. S

    drainige pipe adaptor

    Excuse me for butting in, please keep to your own topic thanks :evil: :evil: :evil: :evil: :evil: :evil: LOL
  20. S

    drainige pipe adaptor

    the original pipe is 135mm OD and approx 100mm inside diameter Nick