    Flue Fumes

    Now you've said it's LPG, thats why it stinks. Nothing you can do I'm afraid. LPG is a 'dirty' burning gas generally anyway.
  2. B

    Potterton puma 100e - hot water OK, CH not igniting

    Everytime you go to one of these, total fail, cust says they can smell TCP from boiler, you know its that dodgy neutral soldering on the top left. The TCP gives it away I suppose! As well as the black scorching and smoke coming from the board!
  3. B

    Flue Fumes

    Either way, if you can smell fumes that bad, the boiler needs a service. Standard flue gas analysis check would probally tell this bod that its burning a little poor and the boiler needs a check. If it does smell, then there must be fairly high CO levels, as Carbon Dioxide has no smell unless...
  4. B

    Potterton puma 100e - hot water OK, CH not igniting

    A dry joint is dull, and gives poor electrical conductivity. Normally happens on the relays on these, excessive heat caused by resistors on PCB and vibration (clickety click) from relays makes it bad connection. Give the relays a gentle prod with an electricians screwdriver and you can...
  5. B

    Flue Fumes

    The flue comes straight out of the wall, to the right of the boiler, which is also next to the back door. All is well normally, but on still-air days, fumes tends to float back in and make the ktichen smell. I would like to just have something to carry the fumes a bit higher up By what...
  6. B

    Blue screen of death

    Must confess, the long running blue screen of death came back to me after a month. Found the problem to be with a corrupt pagefile on my system. Had to disable pagefile manually via registry editor, run error check on hard disk, which deleted corrupt pagefile, then reopen reg edit to make a...
  7. B

    potterton combi 80 noisey boiler

    Chris R If the DHW is sticking on after the tap has been turned off (easily checked by the red light on the PCB), the burner stays on. Now being a dual pass heat exchanger, contained within the waterways, is domestic and central heating water. Logically, if the burner stays on, both waters...
  8. B

    Addition of pump to Gravity HW system.

    Fit an electric immersion heater? Save the hassle of not knowing what he's doing and drop an imeersion in?
  9. B

    Gloworm 30 CI combi problem

    Just a thought, but check the flexible pipe leading to the expansion vessel. They are very small bore, and very flimsy. Went to one of these last year, after several mis-diagnosis by previous monkey pipe slingers (no offence meant to anyone), the pipe had a kink in it, as it can easily turn...
  10. B

    potterton combi 80 noisey boiler

    DHW Flow switch sticking, rushing noise is wax capsule in diverter valve being forced open due to immense latent heat in boiler, thus trying to force heat away from your boiler around the rads. Can be cleaned or ultimately replaced, part costs about £6.
  11. B

    kitchen tap airlocks when i run a bath?!!!!!

    You need to check as previously mentioned that the gate valve is fully opened. If it is ok, then change the seating in the ball valve to a low pressure, thus allowing the feed tank to recover water more quicker than it is being drawn off at, and stop air being sucked in.
  12. B

    Blue screen of death

    Many thanks for the replies Think its sorted now Have downloaded latest drivers and ATi catalyst control center for the graphics card, 8500 radeon, and touch wood it seems to have been running ok for the last 24 hours. Encoded a couple of movies overnight, and voila, no problems as of yet...
  13. B

    Blue screen of death

    I think thats all it says, will get it to crash again in a few moments and post back
  14. B

    Blue screen of death

    The stop messages I get are as follows; Ox000000D1 Ox00000000 Ox00000002 Ox00000000 Ox00000000
  15. B

    Blue screen of death

    Can anyone help? I keep getting the dreaded Blue Screen of Death, with the Stop messages IRQ is less or equal. This only seems to happen when encoding movies, using TMPEG, WinAVi, or VirtualDUB. The corresponding codes it gives me on the stop screen have led me nowhere. I am running; AMD...
  16. B

    Radiator calculations

    You'd normally see how many towels you want to dry cos thats all towel rails are. They aint gonna warm your rusty sheriffs badge when sitting on the polo mint thats for sure. :shock:
  17. B

    britony 80

    Know it sounds daft but have you got TRV's? Are any open? I.e. path of water to flow to? This time of year with milder weather and no external bypass can mislead you into not checking the basics Also, from cold start, does the boiler fire for heating, turn ch on, does boiler fire, and then...
  18. B

    noisy potterton combi 80

    Switch is behind the PCB's on the end of the brass flow switch. Has two wires, (orange if I remember rightly), and screws into the flow switch, with a locknut on it.
  19. B

    noisy potterton combi 80

    The DHW microswitch is sticking After you turn the tap off, the boiler still fires for Hot Water, with all that heat going nowhere, its no surprise your boilers rocking n rolling. Very common fault as on the Potterton Puma. 1)Clean and lubricate DHW switch, or replace if still plays up 2)...
  20. B

    Help...hot water but no central heating

    Well then Gaz How long you been a Poxi engineer for? (potterton/baxi) Is it true, poxi by name, poxi by nature?