  1. R

    Baxi Barcelona lockout

    Bet its not all down to baxi ,how many times did you BG engineer check the water in your heating at a service?, and did it have inhibitor in the system, was the water clean when the boiler was installed? some of its down to what people on a heating system service
  2. R

    Help with Moving rad pipe

    the handles will face where ever you place them straight through valves will spin round on the pipe before you tighten them so if space is a problem make the face inwards
  3. R

    Please help going crazy!!!!!!!!!!!!!!

    sounds like someones mucked up the wiring, you say parts were changed was it like for like?
  4. R

    Help with Moving rad pipe

    ???? lost me there :? Right when you hang the rad it sits about 3 or 4 inches away from the wall ,and has holes at the bottom to take the rad valves (off/on things) which if you get the right ones will point staight down to the floor, and straight on to the pipes if you get it right. one thing...
  5. R

    Help with Moving rad pipe

    It will be a lot easier from under a wooden floor and even possible to use push fit if you leave an access point to get at them later, you can even use crome coated copper to bring the pipes from under the floor to the rad valves,the tappings on towel rads normally face staight down and you will...
  6. R

    Help with Moving rad pipe

    Whatever you do dont put push fit (or compression joints) inside a wall, they are almost certain to leak (and it againts regs) . Get your blow torch out and dont forget the flux.
  7. R

    Ferroli Combi - Bleed point?

    You dont specify which ferroli ,but even the oldest ferroli combi i can find is fitted with an auto air vent, providing its not packed up it will let the air out on its own.
  8. R

    Stopcock leaks

    buy a new stopcock then swap the main body on yours providing the seat is ok you have new stopcock
  9. R

    Worcester Boiler 24CDi - Hot water pressure lost

    get a heating engineer you will save your self a lot of time and money in the long run. you may have now depressurized the expansion vessel this may now cause problems to the heating if you had left it alone you would have safetly used the heating. you really dont know enough to cure...
  10. R

    Turn off a radiator??

    good point :oops:
  11. R

    Worcester Boiler 24CDi - Hot water pressure lost

    oops dont touch that :shock: your looking in the wrong place the water the boiler heats direclty is seperate from the water that flows to you taps the pressure gauge on the boiler has nothing to do with the pressure of the water to your taps. Dont play with the pressure vessel your...
  12. R

    Worcester Boiler 24CDi - Hot water pressure lost

    do you have good water pressure from the cold taps?
  13. R

    Turn off a radiator??

    to turn them off turn the valves clockwise but it sounds like yours are duff , you have to drain down and fit new ones.
  14. R

    Central heating working, but NO HOT WATER

    do a search on three port valve or get someone to have a look, but dont pay 3 grand to bg get qoutes if you want a combi, but your system should be fine with a bit of care
  15. R

    Worcester Boiler 24CDi - Hot water pressure lost

    You said the water was off Did any rubbish got in the pipe, its now blocking the filters in the boiler 24cdi is prone to it. need to get an engineer to sort it out :(
  16. R

    converting vented to sealed system

    Give it a try it might last a couple of hours. Try blocking the vent on the hot water cylinder and changing it to mains fed, just for fun :roll:
  17. R

    Noisy Ferroli

    Was the old pipework and rads powerflushed before the boiler was installed. If not its poss your new boiler has picked up all the rubbish in the system
  18. R

    Combi wizard needed!

    See post Quick fix for coil in hot water cylinder leak to see what we think :)
  19. R

    Do i need anouther pump

    Was the system correctly balanced when the boiler was put in ? Your symptoms sound like a badly balance system or a blockage. Also From what i read these boilers will only work at there best if the flow and return temp is right.