  1. R

    Strap-on

    Unlucky. thats the way it goes try again it should work.
  2. R

    worcester bosch 280 rsf

    iffy flame supervision device, lots of reasons why but some are dangerous get someone to look. could just be a loose wire but you never know.
  3. R

    I really dont think this is quite what I expected....

    could paint some flames on the front ,it would look just like a B&Q fire! :lol:
  4. R

    I really dont think this is quite what I expected....

    the plumbing miracle:wrote "This is the case with Halstead boilers but i feel this is probably the case with all boiler manufacturers." Halstead man not my fovorite, but did you know they have a condensing boiler that fits on a flexible liner ideal for replacing old back boilers say.
  5. R

    leaking toilet

    Its not unusual to get a badly formed pan from Roca, have had to return at least two i can remember for casting faults.
  6. R

    Conventional System

    does the boiler fire up?
  7. R

    toilets

    cistern not filling properly or wrong syphon. possibly too much roughage.
  8. R

    I really dont think this is quite what I expected....

    daglesj i would like to repeat your boiler appears to have one or more flueing faults and should not be used until it is carefully checked, it is unlikely to be serious but it could be. even small amounts of co are dangerous.
  9. R

    Relocating kitchen

    Its more about what it is worth to you, what do you want and what are you prepared to spend to get it.
  10. R

    Two showers

    A pump
  11. R

    speedfit

    "but if you delete the topic then the useful information ." no really useful but amusing :)
  12. R

    16mbar pressure at boiler as opposed to 18 minimum

    Sorry cant let it go. Quoting 6891,The pressure drop between the outlet of the meter and the points to be connected shall not exceed 1 mbar at maximum flow conditions. When sizing pipes it not just the pressure but the gas rate (volume of gas a pipe can pass). So at 16 mbar it is still...
  13. R

    I really dont think this is quite what I expected....

    If the flue leaks water (Condensate) then it can quite possible leak products of combustion, have they checked this? if not then your nice (no sorry horrid) new boiler is classed as immediately dangerous and should be removed from the gas supply. If I did a saftey check on this boiler I would...
  14. R

    16mbar pressure at boiler as opposed to 18 minimum

    maybe if your lucky but its not too much of a problem anyway, only becomes a problem when it goes wrong and worcester blame the gas pressure cause they cant find the fault.
  15. R

    16mbar pressure at boiler as opposed to 18 minimum

    that's what you have to do, given all the information by corgi,the regs and the manufacturer, make a decision is it safe or not. At installation you should always try to abide by the regs but try telling people they cant have a boiler because the gas provider does not supply enough pressure. it...
  16. R

    16mbar pressure at boiler as opposed to 18 minimum

    A point where the gas main is not large enough and they don't have the money or can't be bothered to upgrade the gas main.
  17. R

    16mbar pressure at boiler as opposed to 18 minimum

    here is a spanner in the works . went to a greenstar 35 boiler for service 2 meters from gas meter 28 mm pipework 16 mbar working pressure! after investigation and getting the gas provider in they only have to supply 16mbar working pressure if its on a pinch point . Spoke to corgi and they...
  18. R

    Central Heating comes on same time as Hot water demand

    yep don't play with it. its new and under warrantee wait for the installer or phone worcester (number is in the manual). sounds like a boiler fault.
  19. R

    Wet combustion chamber

    bstr you did the right thing by telling them to seek a qualified engineer. By doing any thing else could leave you in the brown stuff, even if you just turned if off you have then accepted responsibility for it. e.g. you turn it off , they want a bath, turn it back on boiler faults damages...
  20. R

    Creaking Bath

    Whats it made of,if its fiberglass be worried.