  1. C

    Connect to 5 amp round pin lighting circuit

    5a extensions do exist - used by the stage lighting industry. http://www.ebay.co.uk/itm/5A-extension-lead-10m-/190631210408?pt=UK_Computing_CablesConnectors_RL&hash=item2c62816da8
  2. C

    Feeding draw rope into ducting

    this is why cobra rods are worth their weight in gold....
  3. C

    unusual cable - can anyone tell me what it is please

    Always find it strange how split con complied fully with the 16th - I buried loads of the stuff!
  4. C

    Few questions

    usually inside the fuse holder, behind the fusewire. I'm not familiar with your exact unit so can't be sure. Price can vary, for a reputable electrician to do the job you are usually looking at around £450, but depends on what other work is required to bring the install up to scratch...
  5. C

    Few questions

    With regards to the MEM fuseboxes be very careful. I know the type similar to that, but maybe slightly older contains asbestos - that one may well too
  6. C

    Digital timeclock back up facility (Non Diy)

    by any chance are the timers greenbrook? I fit quite a few of them each year - seem to have a 30% failure rate though after 2 years
  7. C

    Underfloor heating - fuse and stat are getting hot !

    why is there a 13a FCU in the circuit if it's on it's on radial? I'd be tempted to run the mat through a contactor and ditch the FCU and replace it with a DP switch.
  8. C

    Hager WeatherProof CU

    because they're used alot more on in europe then over here. There's no point supplying a single pole busbar because often they need a 2p or 3p busbar instead
  9. C

    Electric Underfloor heating - combined FCU/controller?

    why bother with an FCU if it's going to have its own radial?
  10. C

    Down lights - Low voltage or mains?

    I tend to spec for GU10 230v fittings - as they allow easy retrofit of LED lamps. If the fittings are likely to keep their 50w lamps then I'd opt for 12v
  11. C

    Meter Calibration

    I've used the calibration centre before without problems - but I havent had my test kit calibrated in a good few years ( I use a test box and check it monthly)
  12. C

    Method of attaching Earth to cable sheath on TN-S

    I've worked in Moor House in London some of the occupants there have 11kv risers to some of the floors (and some very big backup generators!)
  13. C

    Coloured bulbs for decorative applications

    CFLs are really not suitable for outdoor use - think of all the electronics in the crappy plastic base.... Give me a PM - my business does professional christmas lighting and we have some LED golf ball lamps that actually look like proper filament lamps.
  14. C

    Can i use 3184yh flex in a lighting circuit?

    STOP!!! VAT is charged on rewires on listed buildings. Rewires are classed as maintenance and repair according to HMRC...
  15. C

    Conduit for earth & PIR

    what's wrong with having the conduit as the CPC?
  16. C

    Electric shower

    Is it just me who's a little uncomfortable with the idea of being wet and naked under an electric shower with no RCD protection?
  17. C

    New Consumer Unit

    price seems rather low... I seem to average around the £300 - £450 mark per board plus vat....
  18. C

    TN-C-S or TN-S?

    yes but you're missing the point, PME and TNCS are different things. This is an example of a TNS head on a PME system The outer earth will be derived from the neutral as thats the case in both TNS and TNCS systems....
  19. C

    TN-C-S or TN-S?

    Looks like an older cloth covered cable to me, with an earth braid sweated on... It's a TNS head on a PME system
  20. C

    TN-C-S or TN-S?

    no they are not, PME can exist on TN-S networks