  1. C

    Protecting ceiling boards from downlight springs

    I'd never seen fittings that you had to remove to change a lamp before.. however one of my new customers had. Awful design and resulted in the ceilings getting trashed. Customer spent a lot having 50 + removed and replaced.... I'd suggest employing a decent electrician that doesn't fit...
  2. C

    TN-C-S to TN-S !!!

    I've worked on lots of PME fed street lighting columns. Even had one with a broken PEN conductor over christmas......
  3. C

    unusual cable - can anyone tell me what it is please

    its split concentric - as its has a separate neutral and earth.
  4. C

    What Downlights to use

    they're horrible.....
  5. C

    What Downlights to use

    http://www.alertelectrical.com/prodvar/2957/halers-led-ip65-fire-rated-downlight-warm-white-lamp-white?&utm_source=google-base&utm_medium=web&utm_campaign=google-base-feed
  6. C

    Hook to hang 9kg light fitting!!!

    think Hager klik is up to 10kg?
  7. C

    Wiring details for stand-alone hi-lo PIR

    yes, but how on earth is that set up going to work without the switch set to on?
  8. C

    Wiring details for stand-alone hi-lo PIR

    With that set up you'll have to leave the light switch on to have the light working - you'd need to supply a permanent live in order to get it to work the way you want.
  9. C

    Electric setup 3phase with pics and diagram question

    is it just me or have all the breakers been installed upside down?
  10. C

    superconducting T&E discovered

    Why not take out three phase? Seems a much more sensible idea and future proof. Cost difference between 3 and 4 core SWA is minimal
  11. C

    How to treat this cable

    I've seen exactly the same cable in 1.5mm used in an extension. I guess its the same as singles in conduit?
  12. C

    Putting a single phase RCBO in a three phase board

    hager have two types of SP RCBO - one designed for their single phase boards, and one designed for their 3 phse boards. The latter has longer tails to allow them to reach.
  13. C

    New Garage wiring

    just provide a non RCD protected socket/fcu to the freezer would be the best idea. either use a multicore SWA from the house, or use a split load or RCBO board in the garage? simple
  14. C

    Need an outdoor JB

    Ban, FP200 does have a metal sheath?
  15. C

    house rewire

    toph, where abouts in Bucks are you? I cover most of the area. Perhaps it'd be an idea to have a PIR done on the property - then you'll know how much work really needs doing. The alternative would be to consider rewiring one room at a time, this would be more expensive, but allows the work...
  16. C

    Front garden socket

    solution? http://cgi.ebay.co.uk/MK-Masterseal-Socket-1-Gang-13A-Key-Operated-56487GRY-/230508001045?pt=UK_DIY_Material_Electrical_Fittings_MJ
  17. C

    SWA and RCD protection

    sounds like your electrician may be in the wrong! if the cable is below 50mm or visible then I see no reason for the RCD protection. Where in Hertfordshire are you? I could come and give a second opinion.
  18. C

    SWA and 25mm knockouts

    I always found the MK sockets had 20mm knockouts? unless they've changed?
  19. C

    European Plugs

    dont mean europlugs sorry, i mean shuko type plugs
  20. C

    European Plugs

    I'm picking up the pieces from a very large private contractor, they seem to order all their harnesses ect from greece, and so they come with europlugs attatched. some the the harnesses have obviuously been cut from larger harnesses, and so europlugs have been added. Their method of adding...