Search results

  1. A

    Boiler powered from a normal plug socket, Bodge job??

    Interesting subject. I agree with fitz1 regarding pulling the plug when working on the appliance to be sure of ones safety. However, speaking to a sparks who lives opposite me the other day on this very subject, he says that the reason for fitting spurs is so the earth can't be disconnected, as...
  2. A

    Switchmaster Blue VA1 3 port switch replacement

    The two outlet ports on the Honeywell will be marked 'A' and 'B' (I think B is hot water) check with the instructions. depending on the orientation of the s/master you may have to alter the pipework to make sure that the Honeywell is upright or no further over than 90 degrees. This is so that if...
  3. A

    Switchmaster Blue VA1 3 port switch replacement

    Pipework may require minor alteration. Wiring is as follows: (if you are fitting a Honeywell, first colour is the S/master) Blue to Blue, Earth to Earth, Orange to Orange, Yellow to White, White to Grey, Red to be linked with Orange.
  4. A

    Alpha CB28 Problem

    Please ignore the above ChrisR, it's the horseshoe clip on the diverter valve. Mind went blank. Thanks anyway. :oops:
  5. A

    Alpha CB28 Problem

    Where exactly is that, ChrisR?
  6. A

    Alpha CB28 Problem

    Have client with above 18 month old boiler. She says she has difficulty in getting it to produce hot water, heating works fine. However, every time I turn up (four times now) it works fine. Diverter pin hits micro switch, pump runs, fan comes on, burner lights. I appreciate intermitant faults...
  7. A

    Boiler in Roof Space

    Thanks for all your input. The guard rail was the thing i'd forgotten about, though the remote filling loop seems a good idea.
  8. A

    Boiler in Roof Space

    Good evening Gentlemen, first post and all that. Client has asked me to quote on installing a new boiler in the roof space. Can anyone refresh me the on regs regarding this. I know that the floor must be boarded and there must be a permanent light fitting, both of which this property has...
Back