  1. P

    weeping pipe connection

    no F + E tank shouldn't be there! It should be sitied elsewhere with sufficent support underneath. PFTE will sort it out.
  2. P

    Spares?????

    just phones 'im back. Reckon some plonker has put in a diff valve.
  3. P

    Spares?????

    Thats what i thought but he said its a Padova gas valve with no interupted thermo?!
  4. P

    Spares?????

    Thanks Tony, would have done that tomorrow but was looking for a quick answer!! ( yes i am ! ) :D
  5. P

    Spares?????

    One for the old timers here! Can you still get spares for a Myson Economist WM30/40BF?? Namely a thermo/c. Mate has just phoned me and im not sure !
  6. P

    Pumped shower VS mixer ADVICE please

    How did you come to this conclusion? I take it you have a gravity system and will be feeding the shower from the tank?
  7. P

    looking to make a quick buck!

    would rather poke my eyes out than work for BG!
  8. P

    PRV termination

    absolutly nothing wrong wih the way it has been done, would be daft to wrap tape round the blow off pipe! The discharge of water must be visible and safe. RE your thoughts on manfacturers instruction vs reg.... MI over rule regulations. Now go and find me a left handed spanner!
  9. P

    looking to make a quick buck!

    superb! do you know the name of the firm?
  10. P

    looking to make a quick buck!

    Any of you lads know of any firms hiring temp htg engineers in scotland? Recently pack in with a firm and now working in stirling but just on a temp contract, which will run out within the next 2 weeks. Goin away to travel the world in 12 weeks so just looking for something to give me a wee...
  11. P

    Siphon made of pot

    Ive only ever seen one, had to repair it, can for the life of me remember how i did it tho! Was a a wet behind the ears 2nd year apprentice when i was sent to it, and aparently my boss had told the customer , we can fix anything!
  12. P

    Volkera Excell 80SP hot water probs.

    Needs a service kit. To be fair not every company will carry out the service as per the book and will only hoover out the CC and check pressures etc, without replacing HW diaphrams and cleaning venturi, as should be done.
  13. P

    Your favourite song

    not my all time favourite song, but one of the moment by probably the most underated band of this decade! http://uk.youtube.com/watch?v=Ra3OlfNwqXA
  14. P

    Unstable Bath

    yeah take it back out and run 2x1 cls around the wall so that the bottom lip of the bath sits on top. Bed it onto these with numerous tube of silicone!
  15. P

    Which Sentinel product to use?

    Bear in mind he is REPLACING 5 radiators tony, so all the pipework, existing radiators, pump etc will still be left with magnitite sludge. x300 is for systems less than 6 months old, and really only for cleansing the system of flux residues, swarf etc. Do agree with replacing all the...
  16. P

    Which Sentinel product to use?

    x300 is for new systems. x400 will do the job nicely.
  17. P

    Replacing This Part (photo's Included) Radiator Tail?

    Yeah a 15mm straight boiler into the rad, bit of copper, comp nut and olive onto the new locksheild.