Search results

  1. S

    relighted pilot flame but both c/h & hw not working

    if pilot stays lit and when pump speed turned up boiler fired for a while, it sounds like a circulation problem - is there an overheat stat/interrupter on your boile rin liner with the thermocouple? to the original poster - a service does not include a boiler breakdown, you will have to pay...
  2. S

    Glow Worm Economy Plus 50 problems

    could be some air in system, have known before this knockos out pilot via the overheat interrupter - or the pump could be slow/failing or a dirty system. Try turning pump speed up and see what happens? sometimes if pump is failing/running slow and causing an overheat - turning pump speed up...
  3. S

    relighted pilot flame but both c/h & hw not working

    is the boiler stat turned up? continuity across boiler stat? water in system ....
  4. S

    Ravenheat silver star ls100 combi problem

    with no power to the air pressure switch / fan I'd suspect PCB wa faulty - relay on board may be fauly as suggested before
  5. S

    Thermocouple gone after 5 months!

    I did that on my mum's old boiler a year or so back - after holding the gas button in for well over a minute, the pilot stayed on for some reason - and it lasted a good 3 months until the boiler was replaced. Does anyone know why this happens - ie holding the gas button in longer somehow...
  6. S

    Apollo fanfare 30/50i firing up and cutting out

    let us know what the fault was ...
  7. S

    Thermocouple gone after 5 months!

    Interesting - how do they develop higher resistance contacts Agile?
  8. S

    Apollo fanfare 30/50i firing up and cutting out

    if the gas valve is modulating - check the operation of the modulatuing solenoid too. check every component
  9. S

    Apollo fanfare 30/50i firing up and cutting out

    ok have you chedk the fan (spinning freely) - resistance of the windings? air pressure switch - working ok/tubes not kinked at all / flue clear / venturi fully clear etc? what's the ignition lead like? electrode itself? rectification probe all ok not dirty/misaligned etc? check...
  10. S

    Apollo fanfare 30/50i firing up and cutting out

    has the boiler always been like this? could be a pump overrun issue? could be a blocked manifold somehwere in the system....
  11. S

    Apollo fanfare 30/50i firing up and cutting out

    try checking the pump is running properley?
  12. S

    Baxi combi 130 HE not producing a constant flow of hot water

    some combi's may be sent to lockout with these sympstoms too
  13. S

    Air lock to hot water tank

    no would need plumbing to be re-arranged a bit - but without seeing your pipework it's hard to say if it is the cause or not where your tank is in the loft, there are 2 pipes going/coming from it - follow these down into your system (near the cylinder usually) and then tell me where the pump...
  14. S

    Air lock to hot water tank

    could be drawing air in via the vent - and it's getting trapped there, at probably the highest level in your system
  15. S

    Air lock to hot water tank

    is the pump installed after the vent pipe or is there another feed pipe in between?
  16. S

    Air lock to hot water tank

    where the air vent is that you keep venting, is it on the flow or return pipe form the hot tank? (top or lower pipe)?
  17. S

    Air lock to hot water tank

    gravity hot water systems are quite known to draw air in where the air vent is that you keep venting, is it on the flow or return pipe form the hot tank? (top or lower pipe)?
  18. S

    upstairs radiators get warm when the hot water is one.

    yes they will be then after the pump is there no other valve installed on the flow pipework?
  19. S

    Air lock to hot water tank

    the new rad check that and the pump unions - but see my other post above
  20. S

    Air lock to hot water tank

    where is your vent pipe in relation to the pump? have you got gravtiy hot water?
Back