    Suprima 80 only works with cover open...

    sounds like your flueways (ventilation side) isn't bring enough frsh air into the boiler if it only opens when the case is off whic is very dangerous
  2. S

    Air lock to hot water tank

    seems like you're getting air drawn in often - any union nuts not quite fully tight ??
  3. S

    upstairs radiators get warm when the hot water is one.

    is there 2 of these, one either side of the pump?
  4. S

    upstairs radiators get warm when the hot water is one.

    I don't know much about oil fired boilers but where your pump is, is there a valve closely fitted after it?
  5. S

    Air lock to hot water tank

    has this problem just started or been there all the time? so the boiler fires up for hot water but until you vent the air vent the cylinder doesn't heat up?
  6. S

    upstairs radiators get warm when the hot water is one.

    have you got gravity hot water? if it's just started happening, and there's no diverter valves, could be an anti gravity valve passing -
  7. S

    Thermocouple gone after 5 months!

    Agile is right - thermocouple's can always fluctuate when they are starting to fail - but you need to check the mVoltage at the GV end
  8. S

    i need to replace an old metal central heating header tank

    if the heating is on, then the water will expand a little from the cold feed pipe into the header tank (due to expansion) - if you removing the tank with the heating on you'll get a bit of trouble. Best to really give system a flush and fill up from fresh with new inhibitor
  9. S

    Thermocouple gone after 5 months!

    could be a few things - all gas related though try holding the button in for a longer periold and releasing the button very very slowly
  10. S

    Potterton Prima 40f - ignites, and then... goes out :(

    you do know that if you have just hot water on, then the burner will cycle on and off quite quickly and quite often? have you got a cylinder thermostat or any motorised valves in your system?
  11. S

    Leaking Megaflow Cylinder

    what type of leak fix did you use Axel?
  12. S

    Potterton Prima 40f - ignites, and then... goes out :(

    Rob - if the (main burner) solenoid in thr gas valve is OC as you suggested (and me too) - how do you explain that the burner comes on/boiler fires up for 3-4 minutes at a time before going out...... very strange! that's why pump etc were mentioned and need to be tested
  13. S

    Potterton Prima 40f - ignites, and then... goes out :(

    that was because the engineer who looked at the system suggested no water in system - so I was going on that info - that's why I said let's start again It's not easy going on what people say on here - you;r ebetter off starting from scratch and testing parts yourself - original posters...
  14. S

    Potterton Prima 40f - ignites, and then... goes out :(

    I didn't suggest cold feed Without seeing it it's strange, you need to check/test parts With power to gas valve and gas valve not opening test resistance of coil
  15. S

    Potterton Prima 40f - ignites, and then... goes out :(

    I suggested gas valve fault hours ago - check resistance of gas valve
  16. S

    Boiler Breakdown Learning/Training

    Yeah not too far from Ealing - Mill Hill's a bit firther North I've got a couple of dvds - about learning to use a multimeter I just did a lot myself :)
  17. S

    Potterton Prima 40f - ignites, and then... goes out :(

    could be a rectification fault ...... could be gas valve, pcb, pump..... sounds strange if pilot goes out too - suspect recitification problem - i think your boiler uses same probe for ignition and rectification - may be dirty, out of position, bent under flame a bit, burner dirty...
  18. S

    Expansion vessel re-charging question in general

    good point - I've re-charged 4 and drained about 10 litres after the gauge was on 0 - and all was good - just wondered what ways everyone else did it
  19. S

    Potterton Prima 40f - ignites, and then... goes out :(

    ok lwt;s start again from scratch put h/w or htg on and does the boiler fire up? ..... if so, does it go off again shortly after? if so... does the pilot stay on or go out too?
  20. S

    Boiler Breakdown Learning/Training

    maybe it's the same then :) It's quite good. Have you got any fault finding dvds? I'm from near Northolt if you've heard of that? I'll find out when the next dates are hopefully shortly!