  1. S

    Adding a light in the loft

    Conor. Some photos of your connection will be required in order to help. The landing light Switch wire & neutral would have been acceptable providing you were happy to only be able to operate the loft light when the landing light is on.you dont make any mention of a switch for the loft...
  2. S

    wiring for electric showers again

    John. you state " An electrician will make the final connection and certify it". What exactly do you mean by CERTIFY. If you mean He will Inspect & Test it, then he will be able to issue a Periodic Inspection Report Only.What do you intend to do to satisfy Building Regulations Approval ...
  3. S

    SIMPLE QUESTION REGARDING A FCU AND A CCU

    As ricicle states either one of the SFCUs will do. You ask " can anybody explain the difference between these two ways of wiring the FCU ? ". You dont need to know this if you are bringing in an Electrician.....same answer for the cooker switch enquiry. buy one and the Electrician...
  4. S

    Extractor Fan Ducting?

    Steve. Its common practice to use flexible plastic ducting...never had a problem with it provided it is not torn or holed.You can use 100mm soil pipe if you wish if you have straight runs. The main problem you will encounter as far as extraction rate is the type of fan you...
  5. S

    Shower electrics in surface mount conduit

    Hi Steve, ...You say " does the guy know what he is talking about". You say he was an Electrician so why doubt him ? ..If you went to see your Doctor and he said you had a cold.would you post on a Medical site stating "does the guy know what he is talking about"/ I hope for your...
  6. S

    Garage re-wire

    Greengrass , as your making Alterations to the installation you will need to make sure the existing circuit[s] you are working on are up to standard...this will include verification of RCD protection as spark123 has stated. You will need to test the job properly when completed.If it is in your...
  7. S

    bare earth wires..

    Hi again Coljack. My apologies on not giving a full and concise answer to your original post. ...As Sparkyspike correctly points out the sleeving does has another purpose in addition to Identification and that purpose is for Mechanical and chemical /electrorolytic protection of the...
  8. S

    bare earth wires..

    No the full length of conductor within the enclosure is required to be sleeved
  9. S

    bare earth wires..

    Hi Coljack. in order to comply with the regs ALL conductors require identification.That is the SOLE purpose of the G/Y sleeving it is not an insulating sleeve in any way shape or form. Protective conductors do not require insulation. that is why T&E is allowed to be produced with the bare...
  10. S

    High EFLI

    Bigtom it looks to me you have a TNCS or TNS supply system with a Ze of maybe approx 0.16 ohms [ speculative statement] I would say the two cables with two sockets on each are two ends of an original ring final circuit which somebody has split somewhere...the other cables with one socket on...
  11. S

    Help with Garage electrics

    Dave your reply contained a fair number of assumptions..ie. ifs and buts.. You are right about the possible no requirement for Notification..however there are a lot of consdiderations to be taken into account before advising against it.... If you look at the O.P. it did state he was intending...
  12. S

    Two showers running off one supply

    Chris it would be helpful if before posting you gathered together the correct information for other members to give suitable advice. in your o.p. you indicated the two showers were supplied from the one cable, you are now producing information that suggests this is not in fact the case. ..This...
  13. S

    garden lights

    And if you come to sell your house, what will you say when the Buyers Surveyor asks about the relevant paperwork and checks the B.C data base for the notification.........oops !
  14. S

    Help with Garage electrics

    Hi Dann. I intended to say the B.C will need to be informed Before you start and will inspect at 1st And 2nd fix stages...Sorry ! My mate has a Part P registered friend who will inspect,test and notify Build regs for me The Part P registered Spark can certainly Inspect & Test the...
  15. S

    Help with Garage electrics

    Dann , your obviously doing this work yourself. Be advized that you have a Legal obligation to inform your Local Building Control Dept BEFORE you start, and they will need to inspect it before and after. ...Big fine hanging over you if you dont, they could also force you ro rip it all out again
  16. S

    Electricity to shed/outbuilding

    Industryspark is giving good advice here Axel. There are many factors to be taken into consideration on this proposed supply. If it is intended to utilize the earthing system from the main house then .it is quite possible a 3-core 10mm cable will be required. Industryspark was...
  17. S

    Two showers running off one supply

    Chris. If you have had this second shower fitted then get the idiot back who did it and get him/her to do it properly and safely. if this bodge job was part of the existing electrics when you aquired the property then contact a qualified Electrician to.... A. wire in...
  18. S

    garden lights

    And you may want to tell Mr Building Control about it too if this is in a domestic property !
  19. S

    Two showers running off one supply

    So you have two cables looping at the first shower, I dont think two 10mm cables would fit in the terminals of a shower. maybe two 6mm cables would fit, so lets assume your supply circuit is 6mm. usually the maximum shower that can be installed on this size cable is 8.5 kw { there are factors...
  20. S

    garden lights

    An IP65 rated enclosue springs to mind, or a galvanised Y conduit box suitably sealed.