  1. Serg

    Please help. Got a new deltabox. Trying to fit to an old panel

    Should be easy ) Panel - Deltabell T - T A - (-12v) D - +12V B - Bell (- Strobe) - STB Link tamper as "Deltabell to control panel connection" shows Think if you need backlight and disable if not
  2. Serg

    My Entry Buzzer won't ring

    If you have correct replacement handset I suggest it is problem with wiring. Likely "bussing" you hear in handset is noice from speaker caused by call button shorting incorrect circuit. Check call wire from panel to handset.
  3. Serg

    Texecom Engineer Mode

    Type you engineer code to get engineer menu on display when press Reset button to see Logoff engineer text press Yes and that is. Date and time must be on display in normal mode.
  4. Serg

    DSC 1832 bell wiring issue with Pyronix DeltaPlus

    Bell terminals on DSC panel are for sounder, not for bellbox To triger bell and strobe use PGM 1 and PGM 2 outputs To supply pos and neg to bellbox use AUX+ and - terminals To connect tamper T/T terminals wire it to Z1 and com or any zone accordingly, program as 24h zone and fit end of line...
  5. Serg

    Gate Entry Alarm/Chime

    If you have automatic gates, look at spec of your gate controller. Some may already have dry contacts for connection of external devices to. Some may require fitting relay board. This case you can use simple buzzer or door chime to turn it on/off by gate controller.
  6. Serg

    Texecom Installer in Wolverhampton needed

    Just few quick notes Is door contact for entry/exits missing in you spec? Also LCD keypad is required for the system but it can't be wireless. Com WIFi gives wireless link so it easy to wire up but programming requires some understanding of routing/IP staff. Check if there is a decent wifi...
  7. Serg

    Com WIFI conection

    search any web site what can ping your ip and port 10001, if it will say port open when it is not a router issue. It works if you router set to allow pinging.
  8. Serg

    Texecom Premier Elite Keypad Issue

    That's bit confusing as you screenshoot displaying Keypad 2 - Not fitted I would start with check of correct cabling of keypad To get additional zones on keypad you need to map zones in keypad setup by wintex or engineering menu, page 64 of your manual.
  9. Serg

    Texecom panel lid tamper

    Simply log in engineering mode, when completed use engineer log out option in engineering menu
  10. Serg

    Texecom premier or Scantronic

    Usually terminals on pcb are marked so it says what goes where, sometimes cables are labled as well. If any trouble - use multimeeter to test cores. Open the box and you will see.
  11. Serg

    Texecom premier or Scantronic

    You may find difficult to get end user technical support directly from Scantronic but Texecom is much friendly about it.
  12. Serg

    Texecom Premier Elite Panic activation

    Usually works straight but check keypad option "PA is audible" is on and "PA is delayed" is off. I believe you uploaded changes to the panel!
  13. Serg

    Texecom Premier Elite Panic activation

    Wintex left hand side menu - Keypads -> Keypads options -> PA enabled. Same can be activated by keypad simulator if you go in eng mode to keypad setup- keypad options
  14. Serg

    Replacing damaged CCTV rg59+2 cable in garden

    That is not a big deal to try and see final quality of signal. In theory your HD-SDi signal already lost -12db on 50m distance of RG-59. To do 2 joints use F- connectors. Will require 2 - FF and 4 - F plugs. Benefits of using these connectors are - much more reliable when BNC plugs, not...
  15. Serg

    Texecom Prem Elite Engineer App

    Any user you programmed in panel. By default only one user ID is in the system - Master, as nr 1. code is 5678
  16. Serg

    Upgrading an Existing Alarm System

    Yes. cabling for keypad and keypad is required for new system.
  17. Serg

    Arming back gate

    Fist of all I would suggest to use sealed heavy duty contacts like Knight H10A with armoured sleave or even roller shutter contact rather standard models. Your option may be to link you gate with main panel using Visonic MCT100 and MCR308 wireless transmitter and receiver or similar. Fit...
  18. Serg

    Removing a C&K securitech 800L

    You shut that right way but it just one more battery inside of bellbox. You can consider either climb to it, open and disconnect or leave it for couple of hours for self discharge.
  19. Serg

    Replace Accenta 6 with what????

    I'm also for Premier Elite 24. Good point is you can buy Com-WiFi for it and control it remotely over smartphone app without disturbing anybody else in the house. Self-monitoring is an extra benefit in this case.
  20. Serg

    Door contact issue

    You can't set you alarm because door contact destroyed and you have zone open. That contact also may be you entry/exit zone. Likely blue/white is a tamper and yellow/green is a trigger. Better to post picture to make sure. Yes, you can short trigger wires and it makes zone permanently...