  1. R

    central heating on when not wanted

    CH was switched off yes. when both are off, nothing happens.
  2. R

    central heating on when not wanted

    fitted a new motorized valve today, a sunvic one same as the old one. but i still have hot rads when the CH is switched off. any ideas?
  3. R

    sunvic unishare MV wiring

    yep, but what colour wire does it connect to? should the orange be connected to the same terminal as the pump live and cylinder stat wire?
  4. R

    sunvic unishare MV wiring

    Had a bit of a disaster this afternoon replacing my faulty motorized valve, i accidentally snagged the cable as i moved and the orange wire got pulled from the junction block, and i dont know where its supposed to go! can anyone please help? its a glow-worm space saver mk2 boiler
  5. R

    central heating on when not wanted

    i got the wife to operate the switches on the controller while i monitored the valve. it functioned as it should, is it letting water past? i cant tell by feeling the pipe, its already hot i just checked the b&q reciept, march 2008 i fitted it :roll: could it be anything else?
  6. R

    central heating on when not wanted

    yes, its a new problem. this week
  7. R

    central heating on when not wanted

    the heating is coming on in some but not all radiators upstairs,when CH i turned off at the controller. i've tested the 3 way motorized valve which appears to function correctly and is a b&q MV thats less than 12 months old anyway. faulty tank?
  8. R

    hoover nextra hnwl3136

    The brushes wore down on the motor,i told the wife not to use it but she ignored me. it stopped working,so i fitted new brushes. still dead so i ordered a new motor and fitted it but its still dead. motor is recieving 125volts, when the controller clicks on and off,(this is on drying cycle just...
  9. R

    excessively hot water

    The last ever possible problem you could have right now is a faulty water tank. It either holds water or it doesn't. If it didn't you would know about it! Sorry I cant make it out ... My ball's too foggy tonight :shock: :lol: These tanks never rot, letting the hot water mix with the CH...
  10. R

    excessively hot water

    I dont use the immersion heater, the cylinder stat is clicking at 70 but is set at 55 degrees, is it higher because its failed or because the CH has somehow forced it higher do you think?
  11. R

    excessively hot water

    Further info worthy of mention, i have air bubbling up into the CH f and e tank in the loft, a slow trickle every 30 seconds, and all upstairs radiators needed fully bleeding which i've done. where is all the air coming from? if the two events are linked is it a faulty water tank?
  12. R

    excessively hot water

    Hi all, i'd be grateful for any advice on why my hot water has suddenly (today) become excessively hot? I actually scolded my hand when using the kitchen tap. I checked the thermostat on the immersion tank upstairs and it was set at 55 degrees as i like it, but when i turn the dial with a...