    CH piping issue, block in cold feed pipe

    I'm hoping somebody can help me with a problem my friend is having with his heating system - see diagram below. In the last 2yrs I've helped him get his heating working and as the issues seems to be the same, I thought I would put the question out to see if this can be prevented again...
  2. M

    Scantronic i-on40 single door contact

    it is on its own but you know when wiring the zones up at the panel you have a total of 3 connectors for every 2 zones, one alarm wire from each zone into the corresponding connector and then you join the remaining two together and they go into the middle connector. I will try what you have...
  3. M

    Scantronic i-on40 single door contact

    Thanks Alarm, will give that a go. Just read on another post on this site that I should have the contact on a different zone/circuit. It is on its own zone but does share the wiring at the control panel with another zone, should I have it completely separate? Also should I configure it as a...
  4. M

    Scantronic i-on40 single door contact

    This being a hybrid system, all the detectors and contacts I'm using are wired. I'm using FSL wiring system and I'm using the resistors supplied (2.2K & 4.7k). So the wiring in the PIR's is like this; ___________________4k7 PIR - zone ---------A___/ ____ A ------2k2----T...
  5. M

    Scantronic i-on40 Part Set

    finally figured it out! When you initially power up the system its then when you are prompted to select if you want to use Partitions or Part Set and for some reason I selected Partitions! Oh well, I'll just reset back to factory and start again!
  6. M

    Scantronic i-on40 Part Set

    I can see in the zones attributes an option for Partitions but for all configured zones, this is set to yes by default. Do I need to change this to NO for all? Looking at the manual again it does say that the Part Set option will only appear in a "Level Setting System", how do I set that...
  7. M

    Scantronic i-on40 Part Set

    I'm helping my brother install this system and so far I'm doing well, I've installed other Scantronic systems before so I'm ok with the terminalogy. Basically he needs 2 programs (part set) options, full set and part set but I'm not seeing the part set programming option! Looking at the admin...
  8. M

    Main combi 24 HE issues

    just to let you know that this issue has been resolved and it was the air pressure switch in the end! after another plumber had come and failed to diagnose the problem, my friend called in Main/Baxi and they sorted it for him. Thanks for all your advice and support
  9. M

    Main Combi 24 HE boiler

    can you recommend anybody? he really needs to get this sorted ASAP Thanks
  10. M

    Main Combi 24 HE boiler

    I'm having issues with the same boiler too (see the other 24 HE thread) and having replaced the PCB - which was the faulty part supposedly diagnosed by the engineer that visited I still have the fault! urrrgggg!!!!!! Anyway I was going to try the air pressure sensor next and it you're...
  11. M

    Main combi 24 HE issues

    My friend had a plumber come out last week as it was getting worse, he spent an hour and "somehow" got it going but said if it was to happen again came it was the PCB that was faulty and needed replacing. Well guess what happened?, it started playing up the same night so he brought a new PCB and...
  12. M

    Main combi 24 HE issues

    Anybody in the East London E11 area that is willing to have a look please leave you number here and I will call you to make an appointment. thanks
  13. M

    Main combi 24 HE issues

    can anybody shed some light on how I would test the air pressure switch? Its getting worse and I'm sure its going to pack up very soon. Thanks
  14. M

    Main combi 24 HE issues

    how would I check this components? Also since this post, the boiler is now taking much longer to fire up, approx. 15mins. Could it be that the burner is clogged up and needs cleaning?
  15. M

    Main combi 24 HE issues

    I friend of mine has a problem with this combi he owns, just recently both the dhw and the central heating have been problematic. The current situation is that both the dhw and central heating only comes on after an average of 7mins after the demand has been made, he can hear the fan and the...