Search results

  1. H

    Another Texecom Premier Elite question re: timers

    The delay is in minutes, so 1 minute delay. in global timers unless you changed to area in global, system config 05 you could just put the bell to go on confirmed, that mean the alarm will go through straight away via text, if they activate another zone you get you confirmed and the bell...
  2. H

    Texecom premier 24 problem

    Cool keypad address, the following maybe useful for others. All dips on is engineers keypad address Yes and Menu together will display keypad address top right. Eng = engineer Then number 001 = keypad 1 and so Keypads should be addressed from 1 onwards to max panel can support on...
  3. H

    Fire alarm in communal cellar

    They can advise and it wont cost a penny, depends on what the risks are and what you already have in place.
  4. H

    Texecom premier 24 problem

    Where about's in Manchester are you? If you still having problems i am in the area so may be able to have a look. Look at the programming for the entry exit zone, do you have 1 or two areas assigned to the zone? There should only be one area to a zone. Its difficult to be certain...
  5. H

    Fire alarm in communal cellar

    You are best advised to seek a fire alarm specialist. This is a shared building, you should ask the landlord/ whom ever is responsible for maintaining the building. Ask the fire brigade for free advice first.
  6. H

    alarm for terraced house

    Unfortunately its not as simple as that. Hard wired. wireless and your budget has a lot to do with what options you have available? Along with a proper assessment to work out what you should have. The Main players are what I would stick with, so avoid anything you get at Wickes and B&Q...
  7. H

    Phone cable joining internal

    the extension would have 2 wires connected to 5 and 2 positions you should get a dial tone. If you dont get a ring I believe the ringer is position 3 but not needed for most systems these days. you need to track back to which cables were used in the mater feeding the extension.
  8. H

    Scantronic 9448 Panel

    Most common problems after a power cut is the backup battery and this can cause strange behavior. your saying the systems illuminated, which means power is getting to the unit, so would suggest your fuses are okay, but the battery could be causing issues. If your code or the default...
  9. H

    Texecom Premier Alarm Reset Code problem

    Defaulting the eng code wouldnt work if the user code was the same as the defualt eng. Or he was trying to change the user code to the same code that was the engineers code hence it didnt work And thats what he says was the issue, but from the original query I wasnt sure where he was coming...
  10. H

    Veritas (R8 - i think) PIR change

    The r8 doesnt do resistors and as already pointed out the dector you have specified isnt pet tolerant
  11. H

    Texecom Premier Alarm Reset Code problem

    The system wont let you have two codes the same.
  12. H

    optima compact gen4 alarm

    Which sounder is it connected to?
  13. H

    Texecom Premier Alarm Reset Code problem

    If the codes dont anything whats the keypad displaying
  14. H

    Yale Alarm HSA6400

    sorry typo tje = the on mobile at the time, I would check that zone 4 is entry exit. normally security panels are set zone 1 e/e, zone 2 walk through and the rest guard, default values, and you would have to change these in an engineers programing mode to be different. so when you look at...
  15. H

    Yale Alarm HSA6400

    Sounds like tje zone isnt programmed properly. if its an entry door it should be programmed as entry exit, that would start the timer not familar with these what does it say in log about whats been activated
  16. H

    Accenta G3 makes a 'blip' noise

    Glad its sorted.
  17. H

    Scantronic 9884 tripping in power cuts

    You need to have a look and a test or get someone to do it for you. EightyTwo has given you plenty of things to check over.
  18. H

    Scantronic 9884 tripping in power cuts

    did the alarm trip straight after the power cut or was there a delay?
  19. H

    Looking for A Texecom Installer, Sheffield/NE Derbyshire

    Think you will be surprised that it will cost more to monitor than you would save on your insurance. Years ago a family friend was offered £40 discount on their insurance if it was maintained by nsi or ssaib company and had monitoring, and that could be saved in just a few months and isnt likely...
  20. H

    texecom app

    What panel and version do you have. Press menu 4 on the keypad in day mode it will tell you exactly what you have. The user code, and id is exactly that. ie Master user has id 1, and so on, the code is the code the user would type in the keypad to set/ unset the alarm, if you set the...
Back
Top