  1. H

    Newbie Premier 24 battery question.

    as with sparkymarka on this. You can speed the process up, by down powering completely, connect the new battery press kick start, system powers up on battery and performs battery test, then switch the mains on. Doing this will mean you have to reset the time and date, so probably just...
  2. H

    Texecom 48 - Alarm arms OK, but will not trigger/sound

    First things first. The power cuts should not have done anything at all. However if you have had no power to the unit at all, ie backup failure, you would need to replace the backup battery. Also I would advise you put the system into walk test and test that all the detctors respond...
  3. H

    premier elite 24 area setup

    send me a pm with your email address
  4. H

    farm gate sensors / RF Reed Sensors

    if you have some spare zones, ricochet expansion pack and a contact w in a weather proof box
  5. H

    farm gate sensors / RF Reed Sensors

    what alarm system does he have? Ricochet expansion pack can be added to an alarm system, subject to having spare zones etc. Whats the gate made of?
  6. H

    premier elite 24 area setup

    If you wish I can look at your profile, send pv message with connection details. Then I can advise on all settings.
  7. H

    Veritas r8 plus problem

    Can you get the system into engineering? Default engineers code 1234. 1234 program 19 (takes you to latching walk test). the panel should be beeping 9 times for tamper and 10 for a power fault. press the omit key and the number displayed relates to the tampers. 1 - bell box or...
  8. H

    texecom premier elite 24 programming

    As sparkymarka has suggested, need to know how its wired first, are you using wireless devices or is it all hardwired. What devices do you have on panel and what do you have on the expander? Do the devices walk test okay? Then you can look at the programing.
  9. H

    premier elite 24 area setup

    With it being all the devices, it could still be an expander issue. I would still swap out the expander if you haven't already, or go the hole hog. Swap it all out and setup the system in the office/ at home and see if its still doing it at home, and the replacement is still doing it on...
  10. H

    premier elite 24 area setup

    Okay sparkymarka, that takes in to the time frame I was thinking of but don't remember anything being said about all devices. This is an 8XP-W ? Have you swapped out the 8XP-W, all the devices on the same expander, all running out of battery quickly I would guess its an expander problem...
  11. H

    premier elite 24 area setup

    I have had a device where a battery has lasted 18 months, then the replacement only lasted about 2 months. When I inspected the device after the quick demise there were signs of moisture on the pcb, so put it down to that. The device appeared to have generated a fault, this device was in a...
  12. H

    premier elite 24 area setup

    I agree with sparkymarka regarding the chime. without knowing the original configuration and what was subsequently sent to panel i would be second guessing. However if a user has access to both areas and a keypad is set to one area, both areas areas are armed, the one assigned to the...
  13. H

    premier elite 24 area setup

    Glad its sorted
  14. H

    I have a scantronic 9448 alarm. Power went off one night ala

    Have you replaced the back up battery? The system should have dropped on to battery backup during a power failure if the power went and it went straight into alarm the back up battery probably needs replacing. If you have the engineers code, you should be able to follow the installation...
  15. H

    Texecom veritas 8

    Did you carry out the tamper id test, to find out where the panel says its coming from. If 1 or B on Excel keypad, at the panel end link out the tamper to 0V, retest, does the tamper go away. if the lid is off and you do the test does 1(bell or global) disappear and 3(lid tamper) appear...
  16. H

    pir on entry exit

    The Veritas as with most panels are set with zone 1 as e/e, zone two as a walk through (inhibited entry), zones 3-8 guard (instant alarm). At default the Veritas is on a timed exit, so using a PIR for the entry/exit zone wouldn't be a problem in its self. In general e/e should be...
  17. H

    Texecom Upgrade to Premier/Ricochet

    EXP 1,1 tamp or radio RX tamper relate to the commissioning mode jumper on the -W panels and it can be taken out of commissioning mode just by moving the jumper back. The built in wireless expander is effectively expander address 1. I think its recommended that you leave the system in...
  18. H

    premier elite 24 area setup

    You can set the keypads to local information only. Global, Configuration options, 36 local keypad information, it should only display the areas associated with that keypad. Setting the alarms as separate areas A or B, you need the USER selected for local arming and local disarming.
  19. H

    Texecom veritas 8

    As this is a new system type 1234 program, you should be in engineering mode 19 latching walk test, if the tamper is lit up press omit, the number displayed now will relate to where the tamper is coming from and not the zone number. most common are 1 and 3, 1 being bell tamper or...
  20. H

    Texecom products

    The Elite panel was not available until around 2012. You are asking who is carrying old stock, I would search ebay. You are looking for glass fuses on the veritas panels and Premier 24 around version 8.0 (2007) to 8.28 (2010).