Search results

  1. H

    Accenta G4 Commissioning Problem - Setting Alarm

    what is the system actually displaying? if you set the alarm walk out of the houes and then aftr its set, walk back in does it wourk correctly? just trying to work out when you are actually seeing the fault?
  2. H

    adding pir's to alarm

    V8 has 8 possible zones and no resistors, so max 10 devices on a zone. best to keep on separate zones if possible.
  3. H

    adding pir's to alarm

    Depends on how your system is wired and what power you have left in it. So what alarm system (panel) do you have? If using TEOL then one device per zone EOL then max 3 devices per zone No resistors 10 devices per zone subject to power wire power parallel and...
  4. H

    Premier 24 Battery Fault - Reset how to?

    i have set up the com-ip on premier 24 version 8.33 and can use wintex latest version with no apparent issues including the online keypad and programming all over ip. You can use the remote control function in diagnostics to control the panel, appears to work okay. The apps wont work as...
  5. H

    Premier 24 Battery Fault - Reset how to?

    I maybe able to help if I know exactly what modules you have and what you want to achieve. but given the panel the com-ip may work with wintex with a tweak of the settings of the com-ip module and the comport programmed as not used.
  6. H

    Texecom Premier 48 or Premier 48 Elite, and ComIP - help....

    Usb com and pc com, the comport is set to not used and should work as is, as soon the com port is set for a praticular device or function these modules wont work. The COM-IP if its available in com port setup place it on com1, do a power cycle as suggested if its not already showing an ip as...
  7. H

    Premier 24 Battery Fault - Reset how to?

    Okay the interfacing over ip you may struggle with is the panel wasn't designed to work over ip using the com-ip module originally. You maybe able to get this to work using the ip module in a different mode and using wintex, or creating an app thats been reversed engineered. Currently the...
  8. H

    Texecom Premier 48 or Premier 48 Elite, and ComIP - help....

    When you press Menu then 4 on the keypad in day mode Does it say elite 48 v2.x LS1 OR PREMIER 48 V2.X? As this will determine your options.
  9. H

    Texecom Premier 48 or Premier 48 Elite, and ComIP - help....

    The defualt port is 10001 Can you connect using wintex using the ip address you have specified? If you are having trouble I could look for you by a remote session to your pc with team viewer or something and see how far we can progress, no promises mind as its an old system. How do you...
  10. H

    Veritas R8 Plus Can I...?

    As sparkymarka says. If you want the external bell to ring when its part set you will need to change the settings accordingly.
  11. H

    Fire Safety Systems

    Contact you local fire station they may be able to help and may offer free equipment and advice
  12. H

    Texecom Premier 48 or Premier 48 Elite, and ComIP - help....

    You can use the app except the smart key on the pre elite 48's unless version 10 is used, as advised previously it would probably be simpler to go for the Elite and longer term more cost effctive. To flash the panel to 9 or above a 256 nvm chip from my memory is needed rather than a 128...
  13. H

    Premier 24 Battery Fault - Reset how to?

    Pc interface card? Can you clarify if we talking about the pc com lead or the com-ip and what you want it to do. If its the newish apps for control then the com-ip wont work for the old 24 infortunately.
  14. H

    Scantronic 9800 or 9827 keypad

    can you not give it clean?
  15. H

    Premier 24 Battery Fault - Reset how to?

    You can speed it up it you wish and don't have access to engineer, but have access to master code. down power completely, power up by pressing kick start button, then when powered up turn mains on. (Note1 external bell may ring while no power is supplied to the system). (Note 2 pressing...
  16. H

    Accenta mini gen 4 / AG6 bell box no sound

    A and D are power S strobe B bell T tamper return If you have wired correctly bell test fires bekl strobe test fires strobe. Manually take strobe or bell to 0 volts and strobe or bell should fire accordingly. If you have spare cores you can swap. Accenta A is 0V and D 12V.
  17. H

    Risco agility3 or Wisdom

    The app works on all the elite range (fitted with com ip) Setup an elite 24 with app on iphone the other week worked fine. Doesnt work on pre elite 24 panel. May be thats what you are thinking of. I think its good to have one at the back and front but its like Europlex says to be honest.
  18. H

    Risco agility3 or Wisdom

    Given the number of zones, you could do the 12W which has:- 4 hardwired zones on the panel, and you can have 2 hard wired zones on each keypad and a maximum of 2 keypads and 8 wireless zones. total 16 zones, so why its called the 12 is beyond me. You can still add ip and gsm if...
  19. H

    Alarm System Dilema's

    you dont necessarily need a dual tech in the kitchen because the boiler is in the room. Your are more likely to need a dual tech in say a conservatory. detector placement is probably the single most important thing, then the type of detector. I know some installation with bottom of the...
  20. H

    Risco agility3 or Wisdom

    Everything can be difficult the first time around. Have to think about what support you have available if you are installing yourself just in case. Installation manuals are not always easy to follow. Have you decided if you are going wireless. hybrid yet?