Search results

  1. B

    I've broken my Alarm system: Pyronix Euro46: Please help

    I cant understand how you could have done this in the master manager menu, do the pirs still light up (have power)?
  2. B

    Pyronix issues

    Best option would be to just not have 02 programed on B set until you get another keypad. Programing it as final exit will give you problems when setting A set.
  3. B

    Pyronix issues

    Yes the FX(part ER) would do as you said.
  4. B

    How to route POE cable from loft

    I would drill up at an angle at the top off the wall and hope you miss a wooden joist, you will need a sds drill and big drill bit and some wire rods just go through the mortar not the granite.
  5. B

    Remote control door access

    Net 2 isn't the best for remote access it can do it but it's not the easiest. I would myself look at something like IP hikvision, dahua access stuff.
  6. B

    pyronix central updates

    I do believe they can be upgraded but like you say you need the dongle not done it myself. There are a few different software versions though especially between the international version compared to the UK ones not sure what the differences are though.
  7. B

    wiring 2 Pyronix DeltaBell X external sounders

    Also recommend putting the jumper of one of the bell boxes to scb setting, this means when they are triggered one will be powered by the internal battery. There is a possibility otherwise both bellboxes pulling to much power and popping a fuse.
  8. B

    Alarm battery replacement

    Do you have the engineer code?
  9. B

    Pir 'double nock' settings

    I would just Upgrade the pir to a dual tech one.
  10. B

    Tamper on Pyronix outside bell

    Easiest way is just unplug the sounder on the bell box itself the strobe will still flash.
  11. B

    Tamper on Pyronix outside bell

    Its probably jammed on the back pin on the rear plate, when you clip the internal module into the back plate you need to lift the tamper switch up when you push the module downwards.
  12. B

    Which alarm would you recommend

    I personally would go for the pyronix but that purely because I have far more experience with it.
  13. B

    Pyronix euro46 V10

    Sounds like programing, do you have the master manager and engineer code?
  14. B

    Tamper on Pyronix outside bell

    You will just need a new internal module they just clip in/out with one small screw. That's if you are really that bothered about a tamper on the bell box, how high is it? do you need ladders to get to it? What are the real chances of someone turning up with ladders knowing that the tramper...
  15. B

    Tamper on Pyronix outside bell

    It's more than likely just a faulty tamper switch, try pulling it away from the wall it should be on a pivot making sure it still can move. Also check that the wire from the switch going the bell pcb hasn't been cut and twisted together.
  16. B

    Tamper on Pyronix outside bell

    Sounds like the tamper switch as been wired out or jammed/broken, (if it still works normally with bell test)
  17. B

    Tamper on Pyronix outside bell

    It wouldn't set the panel sounder off but will still sound the bell as soon as you lift the cover unless the engineers hold off as been wired.
  18. B

    Oyn-X IP NVR and Hikvision Cams

    Only a hikvision nvr will use the 8000 port, when using onvif you are basically just sending a video image and will have limited adjustment though the nvr.
  19. B

    Oyn-X IP NVR and Hikvision Cams

    port 8000 is not the video port try rstp port 554
  20. B

    Pyronix wired alarm.

    The enforcer is the wireless system the euro 46 is the wired system but can be fitted with a wireless expander turning it into a hybrid system. They will both work with remote fobs (expander needed for the euro 46)
Back