Search results

  1. B

    Pyronix Enforcer wired BELL

    Having another look at the pic I think there will be wires going into the bell output D+ and B- the red and black wires. Well thats if its a accenta alarm which i think it is. On the the Enforcer input output board wire in. red-12v black-bell yellow-stb white-com that should work. If...
  2. B

    Pyronix Enforcer wired BELL

    Was there not a wire in the bell output on the old panel?
  3. B

    Castle (Pyronix) euro mini entry to reset without engineers code!

    Ive done it a few times but for the life of me cant remember how, its something to do with linking a couple of tampers together and powering up the panel. Sorry I couldn't help more if it comes to me will get back to you.
  4. B

    CCTV for domestic use

    If you are going to fit and buy it yourself i would probably go for hikvision stuff.
  5. B

    CCTV

    Most wireless cameras are not true wireless they need power so you still need to get a cable to them.
  6. B

    Pyronix Deltabell-WE using a 12v PSU

    https://www.powersaver.co.uk/pyronix-batt-es1-battery-for-deltabell-we-mk-2.html
  7. B

    Pyronix Enforcer Input Error

    What do you mean you can see any inputs, whats the keypad telling you when you try to leave the engineers menu?
  8. B

    Pyronix ur2-we

    Not fitted one myself, but will try and help, so you have connected output A to one of the free zones on the alarm (say zone 6) output B to (zone 7) and fault output to (zone 8 )? You need to then program the zones go to change inputs press yes type in what ever zone you connected (zone 6)...
  9. B

    Pyronix Enforcer alarm Siren not loud enough

    You could get another wireless bell box internal module learn that and just put it in your room somewhere (under bed, top of a cupboard) just make sure the tamper is pushed in.
  10. B

    Pyronix Enforcer

    I would stay away from the wireless shocks I've had nothing but problems with them.
  11. B

    Pyronix Enforcer wireless keypad

    If you have the engineer code its not to hard to do, Off the top of my head there is a way of finding the firmware but for the life of me I cant remember sorry will have a think. All I can suggest is go into the engineers and see if you have a option to learn arming stations, how long have you...
  12. B

    Pyronix Enforcer Holdup / attack alarm from keyfob

    To change what all the buttons do, go into engineers, control wireless devises press yes, then press no until key fob buttons, all your options for your buttons are there. I-II together should be set as hold up as default. Used the options to control one of the outputs the other day so it open...
  13. B

    Replacement bell box - not sounder

    Why does it need to be a bell?
  14. B

    Mains powered siren/sounder

    Most DVRs/NVRs have alarm inputs and output relays which can be controlled from the phone app, all you need to do is wire the 12v though the relay to the sounder. Ive used then to control loads of thing from garage doors to big sliding electric gates. The sounder thing is a good idea the master...
  15. B

    Pyronix enforcer v9 digi wifi?

    It can be upgraded but the chances are you will never be able to get it done as its only Pyronix engineers that can do it.
  16. B

    Help installing Pyronix

    address it as 00
  17. B

    Help installing Pyronix

    Yes correct with end of line. In the bell box there is a jumper which turns on the internal battery in the bell box. If power is lost to the bell box, (the alarm panel is ripped off the wall inside, cable cut, bell box ripped off) it will still sound on its internal battery it won't if you...
  18. B

    pyronix enforcer question

    You could program it as a day alarm or PA so will be set all the time, Problem is only way to turn it off would to be put the alarm in engineers mode when you want to go in there.
  19. B

    Help installing Pyronix

    You will be best off using end of line set up as the castle panels come out the box like that 2k2-4k7 and will come with a pack of resisters. The drawing shows you how to do the PIRs with the resisters 4 cores needed to each one + and - and your alarm pair. keypad all you will need is 4 cores...
Back