    bonding

    am i right in thinking that it should always go back to the main board and not to any sub main?
  2. S

    joining beech worktops

    hi what is the best method of joining these types of tops? i've thought about clear siicone or else wood glue Has anyone had experience of these methods or any others? Many thanks
  3. S

    Two new single ovens - do I need two cables to the Fusebox?

    an oven of 3.6kw needs to go on its own 16A circuit. it will probably say that in the manual. some ovens have a cleaning cycle that use full power for 2 hours. thats why you cant apply diversity.
  4. S

    will cooker point cope with new cooker

    you can run a hob and an oven from one 32A switch on a single 32A mcb. pompeygit was right. you use diversity. and 6mm t&e will be ok.
  5. S

    Flex for hob

    not sure but would think you can get it ok company that i work for supply it
  6. S

    Flex for hob

    yea the flex can handle more load than t&e. not absolutely sure but i think its rated to 33A
  7. S

    Wire gas hob into same outlet as elec oven?

    you need to fuse down via a fcu to 3A. you cant connect the ignition straight into a 30A cooker switch if thats what you were implying
  8. S

    Flex for hob

    check the rating of the hob. should be a figure in watts. usually around 6000w for a hob. you should connect a 6mm feed from your cooker switch down to a cooker connection unit. then run 4mm heat resistant flex from that to your hob
  9. S

    equipotential bondin

    yea i see what you are saying i will have another hunt tomorrow. one thought that i have had is that the clamps may be in the next door property as it is a main house with 2 flats with the meters in the house. what if i disconnect the earths one by one at the MET and test? If the readings of...
  10. S

    equipotential bondin

    i've searched for clamps but to no avail. used a long lead and probes directly to the pipework and got those low readings. what im asking is do i have to put new clamps on or is it ok as it is bearing in mind that there definately is continuity.
  11. S

    equipotential bondin

    hi i cant find any earth clamps connected to the 2 stop cocks in the property. i did a continuity test and am getting around 0.04 ohms reading. does it matter that i cant locate the claps and that i can take it as read that the pipes in question are bonded? also need to extend the...
  12. S

    rcd protection

    secure h&s = health and safety
  13. S

    rcd protection

    umm just was wondering because its one of the ways that my h&s have said that is an acceptable way of dealing with the new regs
  14. S

    rcd protection

    does this sound right? one way to deal with 17th regarding rcd protection if no rcbo's will work would be to take for instance the ring main out of the mcb and take it through a stand alone rcd unit and back into the mcb
  15. S

    Isolator between meter and CU

    half the places i work in dont have a tag on the main fuse so i wouldnt worry. and i dont personally do any major work eg new CU's without pulling the main fuse
  16. S

    ovens on ring main

    he could run it in 4mm T&E and put a double socket on the end of it. he can then plug in the hob ignition and oven on 13A fuses.
  17. S

    ovens on ring main

    you wouldnt be able to plug both ovens into a double socket with 13A fuses in if the ovens are rated at 16A each. i would put them on their own 16A radial in 4mm2.
  18. S

    New Shower Consumer Unit

    wouldnt the rccb count as a single point of isolation? or are you suggesting a separate main switch to isolate that 2way CU?
  19. S

    filling in niceic certs

    when you have a sub main you state it in the first row before circuit one. do you still have to fill out every box on the first row on the niceic forms?
  20. S

    Anyone know where I can get a Wylex Circuit Breaker

    pretty sure that proteus ones fit those wylex boards