  1. BDL

    Boiler backfires

    When was it last serviced? Could be spark gap too small, duff spk gen, poor inlet working pressure at ignition. Ideal have a new improved ignition board now(pcb 41) which sparks then opens gas valve. Instead of sparking and opening gas valve at the same time.
  2. BDL

    When you can't DIY, anyone have experience with British Gas?

    £100 including expansion vessel
  3. BDL

    When you can't DIY, anyone have experience with British Gas?

    To replace the expansion vessel on the Response 120 you need to have either clearance at the right hand side or top of boiler to remove it, otherwise it is a boiler off the wall job. Fairly easy to replace £100 is a fair price to pay, shouldn't take longer than an hour. Bear in mind that Bgas...
  4. BDL

    intermittent fault with central heating and hot water

    The Ideal Minimiser can suffer from lockout in the mornings, usually caused by damp probes. Get your engineer to try the following; Adjust spark gap to 5mm ensure detection probe is aligned with burner ports. Increase burner pressure by 1mb Remove the pcb 37 and fit a pcb 41 Ideal...
  5. BDL

    Potterton Kingfisher RS50 Floor Boiler

    Nelson, sounds like it needs a service. Pilot burner probably blocked and burner pressure may need checking. A full service should see it right again.
  6. BDL

    Combi boiler in loft (timber framed building regs)

    As I said before, good luck. By the way A plumber is not a heating engineer, and a heating engineer is not a plumber!
  7. BDL

    Combi boiler in loft (timber framed building regs)

    Getting a little upset? So you are too tight to pay out money for the regs? you want them for free? I have the current gas safety regs and British standards to hand and refer to them almost on a daily basis. As I am also corgi reg'd I have a back up technical line and relevant info needed. I...
  8. BDL

    Combi boiler in loft (timber framed building regs)

    So you have really answered your own question, have you not? You can't find the regs that you need, but you are competent in fitting a boiler? Part of the acs assessments that all corgi Engineers and Plumbers have to pass at great expense is to demonstrate an ability to find the regs...
  9. BDL

    Combi boiler in loft (timber framed building regs)

    Isn't that the point of getting a qualified Corgi guy to install the boiler? Have you already arranged for someone to commission?, I think you may struggle there, I can't think of any Corgi guys that would go in and put their name to an installation that was not at least over seen by them.
  10. BDL

    Even More Suprima 50 lockouts

    We normally fit the Ideal Classic boiler in conjunction with the Gledhill. It is a proven reliable boiler. Cost depends on system etc
  11. BDL

    ideal boiler not firing

    I'm guessing that you either have an elan or a Classic, more details would help but if it was the gas valve you should expect to pay approx. 140 pounds for the valve plus what ever labour charge the engineer quotes. It would be a fairly easy diagnosis by any heating engineer what the fault is...
  12. BDL

    heating on whenever hot water on

    Yep agree fully, most probably the motorised valve is letting by, if that is the case the whole valve will need to be replaced. Price depends on size of valve and how much the heating engineer charges per hour. Ball park figure approx. 150 pounds
  13. BDL

    ideal boiler not firing

    It depends what boiler you have, give me some more info and I will try and help you.
  14. BDL

    ideal boiler not firing

    What boiler is it? Ideal make lots of different boilers. From the sound of things I would say gas valve not opening for main burner.
  15. BDL

    IDEAL SPRINT - what bit is this?

    That is your calorifier, it should look like a round grey unit with several pipes coming out of it. If you plan to remove it I wish you well, they were a good boiler at the time but tend to leak more often than not when disturbed.( Even in places you haven't touched) DON'T TURN THE BOILER...
  16. BDL

    boiler on/off

    Ian the 3 things on the boiler that could cause this cycling on/off problem are: thermister ( black lead from pcb to top left of heat exchanger) Potentiometer ( from the back of the black knob on the front to the pcb) Pcb- ( board 25c) The only sure way to tell is to check the...
  17. BDL

    Potterton Netaheat Boiler Leak Noise

    Precisiely my point. You removed the outer casing!!. That can be potentially lethal if the seal is not sound or is not correct.
  18. BDL

    No hot water - please help

    How old is the boiler? Has it been serviced recently? May be flow switch or thermister related
  19. BDL

    sime super 90 hotwater problems

    What is the flowrate at the taps? You should be looking for about 11 litres per minute at a 35 degree rise.
  20. BDL

    Potterton Netaheat Boiler Leak Noise

    Kash, if you ever listen to one piece of advice then please let it be this, If you have removed the front case of the boiler and poked around inside PLEASE CALL OUT A REGISTERED CORGI ENGINEER to look at the boiler. If you do a search on the Potterton Netaheat you will see why. Not meaning...