  1. G

    Bosh 240 diverter valve replacement.

    yeah definately good call holty
  2. G

    CH won't come on - motorised valve problem?

    head can be removed on honey well unless it is really old in which case it cant and you can tell as you will see a red seal between head and body
  3. G

    ideal isar he24

    what is on zero display or pressure guage
  4. G

    Does my Burner need replacing?

    if he was a professional and he was registered then why are you doubting him isnt that why you got him in in the first place to check your boiler over (service) and he raised the issues thad need adressing
  5. G

    Bosh 240 diverter valve replacement.

    sorry guys im thinking off 24cdi thats coz i just got glasgow gas a book on a cdi i still have book on 240 if u require it
  6. G

    Bosh 240 diverter valve replacement.

    give me your email addy and ill send you a book yer its bottom left behind plate heat exchanger and charging link assy
  7. G

    Bosh 240 diverter valve replacement.

    dead easy to do never used instructions on the first one i did. it may say in ur user manual but basically valve off all connections under boiler release pressure drain out water and just start taking everything off thats in your way being carefull not to break the black plasic charging assembly
  8. G

    vaillant turbomax plus 828E power supply problems

    if its doing the main fuse my money is on the pump unplug the pump and try again,
  9. G

    CH won't come on - motorised valve problem?

    sounds like your loosing the neutral to motor somewhere in the valve
  10. G

    glow worm micron 70ff

    true forgot about that cheers doitall
  11. G

    glow worm micron 70ff

    been to a glow worm micron customer complaining of gas smells out of flue FGA it readings way out 2500ppm checked burner only couple of burners lit jets were blocked, fitted new jets still same reading but now all burners lit, gas pressure correct, gas rated also correct, but did notice alot...
  12. G

    Worcester 35CDi problems

    am i on the correct website or is this place just full of stalkers? im a phantom of all knowledge
  13. G

    Worcester 35CDi problems

    Legion............not me
  14. G

    Worcester 35CDi problems

    yeah big national firm called BRITISH GAS SORRY thats just a big joke
  15. G

    Too much pressure

    were on about a fill loop passing bylaws state a fill loop should be removed so how can it pass? but boilers with built in fill loop (vaillant) cant be disconected worcester has charging key so thats the same as removing fill loop so it cant pass
  16. G

    Too much pressure

    Because the boiler won't work if the charging key is in the fill position. ???
  17. G

    Too much pressure

    ahh I never said its impossible i said TECHNICALLY so im not saying it is impossible bylaws state the fill loop should be removed as to stop water contamination etc but as you have pointed this out its not true i dont know how they do it but the word technically
  18. G

    How much water does radiator hold?

    we emptied 4 radiators out of a hotel 700x 500 and rads were full and only filled a buckett half way in total, so depends on your rads these were som very old naff rads with a 15mm bar at top and 15mm bar at bottom and the rest was mesh POINTLESS
  19. G

    Too much pressure

    technically it should be impossible for a fill loop to pass as it shouldnt be connected when not in use
  20. G

    Room thermostat not turning off the heating

    should be easy to fix first you need to make sure you have 240V from your time clock CH ON to the roomstat then from your room stat (when stat is calling for heat) to the brown wire of the CH zone valve and you should now have 240 on grey or the orange wire of the zone valve (one of these...