Search results

  1. S

    17th Edition - Cable Capacity - Which Method ?

    If a cable was run inside a conduit which was run inside thermal insulation ( so as to completely encapsulate ) the conduit and thus the cable it would not be possible for the cable to dissipate heat ? So is the 32A rating for Method A wrong ?
  2. S

    17th Edition - Cable Capacity - Which Method ?

    Hi Looking at Table 4D5 Method A ( cable in conduit in an insulated wall ) a 6 sq.mm cable is derated to 32A. Where would this method be applicable ?
  3. S

    Current Carrying Capacity - Just wanted to check ?

    Cheers Scarypants - much appreciated !
  4. S

    17th Edition - Cable Capacity - Which Method ?

    Scarypants The cable runs pretty much trough out the run touching the side of the insulation. The cable run is approx. 15m.
  5. S

    17th Edition - Cable Capacity - Which Method ?

    Hi In my house we have the PVC Twin + Earth 6 sq.mm cable clipped to the side of a timber ceiling joist which is 200mm deep. The cable is in the centre of the joist. The same cable after crossing the ceiling drops down in a stud partition which is 150mm deep. It is not clipped to the...
  6. S

    Current Carrying Capacity - Just wanted to check ?

    Rebuke The consumer unit is fitted close to the ceiling. The cable comes out of the CU up into the ceiling where it is clipped 1/2 way down the 200mm deep ceiling joists. It thus runs through the ceiling space between the ground floor and the upper floor. It then drops down the 150mm...
  7. S

    Current Carrying Capacity - Just wanted to check ?

    Rebuke The cable is clipped directly to the timber joints. The mineral wool insulation was then fitted right up against the cable. The cable does not lie on top of the plasterboard. When you say inner wall surface do you mean the rear of the plasterboard ?
  8. S

    Current Carrying Capacity - Just wanted to check ?

    Rebuke Cheers - am I correct to say that the cable can handle 35A ?
  9. S

    Current Carrying Capacity - Just wanted to check ?

    Hi The insulation is to the side. One of the sides ( flat face ) of the cable is directly clipped to the timber frame. The strange this is that the hob has a total theoretical loading of 10.8kW, which assuming 230V is a current rating of 47A, but it only draws 34A ?
  10. S

    Current Carrying Capacity - Just wanted to check ?

    Hi I was wondering if someone could check my understanding of the current capacity of a PVC insulated Twin + Earth 6 sq.mm cable which we have installed. The cable has been clipped direct to the timber frame and has mineral wool insulation placed to the side of it. It is not grouped...
  11. S

    Foundation for Balcony Leg

    Thanks to everyone - much appreciated. :D
  12. S

    Foundation for Balcony Leg

    Cheers Shytalkz The ground material lying around the construction is typical of what I dug out. Stones and a course sandy material - no top soil and no vegetation. I was paranoid that I did not go deep enough all the way don to virgin formation ? This area had laid undisturbed for...
  13. S

    Calling Noseall

    Morning Noseall I see you are on line. Was wondering if you could give me your comments on my previous post "Foundation for Boundary Post". Many thanks.
  14. S

    Calling Shytalkz

    Hi Shytalkz I uploaded a picture of my balcony footing. You kindly helped me on this before. I would be interested to hearing if your advice changes now that there is a photo of what we did. The post is called "Foundation for Balcony Leg" Cheers - much appreciated.
  15. S

    Movement Bead NOT to be used over Structural Movement Joints

    Hi Many thanks. I've been looking at a lot of new houses where the integral movement bead has been used on them all externally in the roughcast ? The older houses have the stop beads filled with mastic. Cheers
  16. S

    Movement Bead NOT to be used over Structural Movement Joints

    Please see attached screen captures from Expamet web site.
  17. Untitled

    Untitled

  18. Untitled

    Untitled

  19. Building

    Building

  20. S

    Foundation for Balcony Leg

    Hi I have uploaded a picture of the footing. The concrete blocks have been used to come up to what will be the finished ground level. Any other comments ?
Back
Top